English
Language : 

TLC59116 Datasheet, PDF (13/30 Pages) Texas Instruments – 16-CHANNEL Fm+ I2C-BUS CONSTANT-CURRENT LED SINK DRIVER
TLC59116
www.ti.com .................................................................................................................................................. SLDS157A – FEBRUARY 2008 – REVISED APRIL 2008
Mode Register 1 (MODE1)
Table 3 describes Mode Register 1.
Table 3. MODE1 – Mode Register 1 (Address 00h) Bit Description
BIT
SYMBOL
ACCESS (1)
VALUE
DESCRIPTION
7
AI2
0 (2)
Register auto-increment disabled
R
1
Register auto-increment enabled
6
AI1
0 (2)
Auto-increment bit 1 = 0
R
1
Auto-increment bit 1 = 1
5
AI0
0 (2)
Auto-increment bit 0 = 0
R
1
Auto-increment bit 0 = 1
4
SLEEP
R/W
0 (2)
Normal mode(3)
1
Low-power mode. Oscillator off(4).
3
SUB1
R/W
0 (2)
Device does not respond to I2C bus subaddress 1.
1
Device responds to I2C bus subaddress 1.
2
SUB2
R/W
0 (2)
Device does not respond to I2C bus subaddress 2.
1
Device responds to I2C bus subaddress 2.
1
SUB3
R/W
0 (2)
Device does not respond to I2C bus subaddress 3.
1
Device responds to I2C bus subaddress 3.
0
ALLCALL
R/W
0
Device does not respond to LED All Call I2C bus address.
1 (2)
Device responds to LED All Call I2C bus address.
(1) R = read, W = write
(2) Default value
(3) Requires 500 µs maximum for the oscillator to be up and running once SLEEP bit has been set to logic 1. Timings on LED outputs are
not ensured if PWMx, GRPPWM, or GRPFREQ registers are accessed within the 500-µs window.
(4) No blinking or dimming is possible when the oscillator is off.
Mode Register 2 (MODE2)
Table 4 describes Mode Register 2.
Table 4. MODE2 – Mode Register 2 (Address 01h) Bit Description
BIT
SYMBOL
ACCESS (1)
VALUE
DESCRIPTION
7
EFCLR
R/W
0 (2)
Enable error status flag
1
Clear error status flag
6:4
R
000(2) Reserved
5
DMBLNK
R/W
0 (2)
Group control = dimming
1
Group control = blinking
3
OCH
R/W
0 (2)
Outputs change on Stop command(3)
1
Outputs change on ACK
2:0
R
000(2) Reserved
(1) R = read, W = write
(2) Default value
(3) Change of the outputs at the Stop command allows synchronizing outputs of more than one TLC59116. Applicable to registers from 02h
(PWM0) to 17h (LEDOUT) only.
Copyright © 2008, Texas Instruments Incorporated
Submit Documentation Feedback
13