English
Language : 

PCA9554DW Datasheet, PDF (13/36 Pages) Texas Instruments – REMOTE 8-BIT I2C AND SMBus I/O EXPANDER WITH INTERRUPT OUTPUT AND CONFIGURATION REGISTERS
Not Recommended for New Designs
PCA9554
www.ti.com ........................................................................................................................................................ SCPS128B – JULY 2006 – REVISED AUGUST 2008
I2C INTERFACE TIMING REQUIREMENTS
over operating free-air temperature range (unless otherwise noted) (see Figure 10)
fscl
tsch
tscl
tsp
tsds
tsdh
ticr
ticf
tocf
tbuf
tsts
tsth
tsps
tvd(data)
tvd(ack)
Cb
I2C clock frequency
I2C clock high time
I2C clock low time
I2C spike time
I2C serial-data setup time
I2C serial-data hold time
I2C input rise time
I2C input fall time
I2C output fall time
10-pF to 400-pF bus
I2C bus free time between stop and start
I2C start or repeated start condition setup
I2C start or repeated start condition hold
I2C stop condition setup
Valid data time
SCL low to SDA output
valid
Valid data time of ACK condition
ACK signal from SCL low
to SDA (out) low
I2C bus capacitive load
STANDARD MODE
I2C BUS
MIN
MAX
0
100
4
4.7
50
250
0
1000
300
300
4.7
4.7
4
4
300
0.3
3.45
400
(1) Cb = Total capacitive load of one bus in pF
FAST MODE
I2C BUS
MIN
MAX
0
400
0.6
1.3
50
100
0
20 + 0.1Cb(1)
300
20 + 0.1Cb(1)
300
20 + 0.1Cb(1)
300
1.3
0.6
0.6
0.6
50
UNIT
kHz
µs
µs
ns
ns
ns
ns
ns
ns
µs
µs
µs
µs
ns
0.1
0.9 µs
400 ns
SWITCHING CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted) (see Figure 11 and Figure 12)
PARAMETER
tiv Interrupt valid time
tir Interrupt reset delay time
tpv Output data valid
tps Input data setup time
tph Input data hold time
FROM
(INPUT)
P port
SCL
SCL
P port
P port
TO
(OUTPUT)
INT
INT
P7–P0
SCL
SCL
STANDARD MODE
I2C BUS
MIN
MAX
4
4
200
100
1
FAST MODE
I2C BUS
MIN MAX
4
4
200
100
1
UNIT
µs
µs
ns
ns
µs
Copyright © 2006–2008, Texas Instruments Incorporated
Product Folder Link(s): PCA9554
Submit Documentation Feedback
13