TIBPAL20L8-7C Datasheet, PDF (12/20 Pages) Texas Instruments – HIGH-PERFORMANCE IMPACT-X E PAL CIRCUITS | |||
|
◁ |
TIBPAL20L8-10M, TIBPAL20R4-10M, TIBPAL20R6-10M, TIBPAL20R8-10M
HIGH-PERFORMANCE IMPACT-X ⢠PAL® CIRCUITS
SRPS005D â D3307, OCTOBER 1989 â REVISED NOVEMBER 1995
electrical characteristics over recommended operating free-air temperature range
PARAMETER
VIK
VOH
VOL
IOZHâ¡
IOZLâ¡
II
IIHâ¡
I/O ports
All others
IILâ¡
IOS§
ICC
Ci
Co
Cclk
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0,
f = 1 MHz,
f = 1 MHz,
f = 1 MHz,
TEST CONDITIONS
II = â 18 mA
IOH = â 2 mA
IOL = 12 mA
VO = 2.7 V
VO = 0.4 V
VI = 5.5 V
VI = 2.7 V
VI = 0.4 V
VO = 0.5 V
Outputs open
OE = VIH
VI = 2 V
VO = 2 V
VCLK = 2 V
MIN TYPâ MAX
â0.8 â 1.5
2.4 3.2
0.3 0.5
20
â 0.1
1
100
25
â 0.08 â 0.25
â 30 â70 â 130
140 220
5
6
6
UNIT
V
V
V
µA
mA
mA
µA
mA
mA
mA
pF
pF
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITION
MIN TYPâ MAX UNIT
without feedback
62.5
fmax¶
with internal feedback
(counter configuration)
62.5
MHz
with external feedback
50
tpd
I, I/O
O, I/O
R1 = 390 â¦,
1
6
10 ns
tpd
CLKâ
Q
R2 = 750 â¦,
tpd#
CLKâ
Feedback input
See Figure 6
1
4
10 ns
5 ns
ten
OEâ
Q
1
4
10 ns
tdis
OEâ
Q
1
4
10 ns
ten
I, I/O
O, I/O
1
6
12 ns
tdis
I, I/O
O, I/O
1
6
10 ns
â All typical values are at VCC = 5 V, TA = 25°C.
â¡ I/O leakage is the worst case of IOZL and IIL or IOZH and IIH respectively.
§ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. VO is set at 0.5 V to
avoid test problems caused by test equipment ground degradation.
¶ See section for fmax specifications. fmax with external feedback is not production tested but is calculated from the equation found in the fmax
specification section.
# This parameter applies to TIBPAL20R4â and TIBPAL20R6â only (see Figure 4 for illustration) and is calculated from the measured fmax with internal
feedback in the counter configuration.
12
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |