English
Language : 

TL1431_10 Datasheet, PDF (11/27 Pages) Texas Instruments – PRECISION PROGRAMMABLE REFERENCE
www.ti.com
6
TA = 25°C
5
PULSE RESPONSE
Input
TL1431
PRECISION PROGRAMMABLE REFERENCE
SLVS062L – DECEMBER 1991 – REVISED OCTOBER 2007
VI
220 Ω
Output
4
3
Output
Pulse
Generator
f = 100 kHz
50 Ω
2
1
0
01 2 3 45 67
t − Time − µs
Figure 14.
STABILITY BOUNDARY CONDITIONS
100
A-VKA = VI(ref)
90 B-VKA = 5 V
C-VKA = 10 V
80 D-VKA = 15 V
IKA = 10 mA
TA = 25°C
70
Stable
60
Stable
B
C
50
40
A
30
D
20
10
0
0.001
0.01
0.1
1
10
CL − Load Capacitance − µF
GND
TEST CIRCUIT FOR PULSE RESPONSE
150 Ω
IKA
VI
+
CL
VBATT
−
TEST CIRCUIT FOR CURVE A
R1 =
10 kΩ
CL
R2
IKA
150 Ω
VI
+
VBATT
−
TEST CIRCUIT FOR CURVES B, C, AND D
A. The areas under the curves represent conditions that may cause the device to oscillate. For curves B, C, and D, R2 and V+ are
adjusted to establish the initial VKA and IKA conditions, with CL = 0. VBATT and CL then are adjusted to determine the ranges of
stability.
Figure 15.
Copyright © 1991–2007, Texas Instruments Incorporated
Product Folder Link(s): TL1431
Submit Documentation Feedback
11