English
Language : 

TL1431M_15 Datasheet, PDF (11/32 Pages) Texas Instruments – PRECISION PROGRAMMABLE REFERENCE
www.ti.com
6
TA = 25°C
5
PULSE RESPONSE
Input
TL1431
SLVS062M – DECEMBER 1991 – REVISED APRIL 2012
VI
220 W
Output
4
3
Output
Pulse
Generator
f = 100 kHz
50 W
2
1
0
01 2 3 45 67
t − Time − µs
Figure 14.
GND
TEST CIRCUIT FOR PULSE RESPONSE
STABILITY BOUNDARY CONDITIONS
100
A-VKA = VI(ref)
90 B-VKA = 5 V
C-VKA = 10 V
80 D-VKA = 15 V
IKA = 10 mA
TA = 25°C
70
Stable
60
Stable
B
C
50
40
A
30
D
20
10
0
0.001
0.01
0.1
1
10
CL − Load Capacitance − µF
150 W
IKA
VI
+
CL
VBATT
−
TEST CIRCUIT FOR CURVE A
R1 =
10 kW
CL
R2
IKA
150 W
VI
+
VBATT
−
TEST CIRCUIT FOR CURVES B, C, AND D
A. The areas under the curves represent conditions that may cause the device to oscillate. For curves B, C, and D, R2,
and V+ are adjusted to establish the initial VKA and IKA conditions, with CL = 0. VBATT and CL then are adjusted to
determine the ranges of stability.
Figure 15.
Copyright © 1991–2012, Texas Instruments Incorporated
Product Folder Links: TL1431
Submit Documentation Feedback