SLVS302B – DECEMBER 2000 – REVISED OCTOBER 2015
TPS6030x Single-Cell to 3-V or 3.3-V, 20-mA Dual Output, High-Efficiency Charge Pump
1 Features
•1 Input Voltage Range From 0.9 V to 1.8 V
• Regulated 3-V or 3.3-V Output Voltage
• Up to 20-mA Output Current
• High Power Conversion Efficiency (up to 90%)
Over a Wide Output Current Range, Optimized for
1.2-V Battery Voltage
• Additional Output With 2 Times VIN (OUT1)
• Device Quiescent Current Less Than 35 µA
• Supervisor Included; Open Drain or Push-Pull
Power Good Output
• Minimum Number of External Components
– No Inductors Required
– Only Five Small, 1-µF Ceramic Capacitors
Required
• Load Isolated From Battery During Shutdown
• Micro-Small 10-Pin MSOP (VSSOP) Package
2 Applications
• Pagers
• Battery-Powered Toys
• Portable Measurement Instruments
• Home-Automation Products
• Medical Instruments (Like Hearing Instruments)
• Metering Applications Using MSP430 Micro-
Controller
• Portable Smart Card Readers
3 Description
The TPS6030x devices are a family of switched-
voltage converters designed specifically for space-
critical battery powered applications.
The TPS6030x step-up, regulated charge pumps
generate a 3-V (±4%) or 3.3-V (±4%) output voltage
from a 0.9-V to 1.8-V input voltage (one alkaline,
NiCd, or NiMH battery).
Only five small 1-µF ceramic capacitors are required
to build a complete high efficiency DC-DC charge
pump converter. To achieve the high efficiency over a
wide input voltage range, the charge pump
automatically selects between a 3× or 4× conversion
mode.
Output 1 (OUT1) can deliver a maximum of 40 mA
from a 1-V input, with output 2 (OUT2) not loaded.
OUT2 can deliver a maximum of 20 mA from a 1-V
input, with OUT1 not loaded. Both outputs can be
loaded at the same time, but the total output current
of the first voltage doubler must not exceed 40 mA.
For example, the load at output 1 is 20 mA and the
load at output 2 is 10 mA.
Device Information(1)
PART NUMBER
PACKAGE
BODY SIZE (MAX)
TPS60300,
TPS60301,
TPS60302,
TPS60303
VSSOP (10)
3.05 mm × 4.98 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Typical Application Schematic
Alkaline Battery Operating Time
Operating time (hours) with an alkaline battery
(2000 mAh) until power good goes low at IL = 20 mA
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.