English
Language : 

TPS60300 Datasheet, PDF (1/22 Pages) Texas Instruments – SINGLE-CELL TO 3.0-V/3.3-V, 20-mA DUAL OUTPUT, HIGH-EFFICIENCY CHARGE PUMP
TPS60300, TPS60301, TPS60302, TPS60303
SINGLE-CELL TO 3.0-V/3.3-V, 20-mA DUAL OUTPUT,
HIGH-EFFICIENCY CHARGE PUMP
SLVS302A – DECEMBER 2000 – REVISED MARCH 2001
features
D Regulated 3-V or 3.3-V Output Voltage With
up to 20-mA Output Current From a 0.9-V to
1.8-V Input Voltage Range
D High Power Conversion Efficiency (up to
90%) Over a Wide Output Current Range,
Optimized for 1.2-V Battery Voltage
D Additional Output With 2 Times VIN (OUT1)
D Device Quiescent Current Less Than 35 µA
D Supervisor Included; Open Drain or
Push-Pull Power Good Output
D No Inductors Required/Low EMI
D Only Five Small, 1-µF Ceramic Capacitors
Required
D Load Isolated From Battery During
Shutdown
D Microsmall 10-Pin MSOP Package
description
applications
D Pagers
D Battery-Powered Toys
D Portable Measurement Instruments
D Home Automation Products
D Medical Instruments (Like Hearing
Instruments)
D Metering Applications Using MSP430
Microcontroller
D Portable Smart Card Readers
EN
C1–
VIN
C1+
OUT1
DGS PACKAGES
(TOP VIEW)
1
10
2
9
3
8
4
7
5
6
PG
GND
C2–
C2+
OUT2
The TPS6030x step-up, regulated charge pumps
generate a 3-V ±4% or 3.3-V ±4% output voltage
from a 0.9-V to 1.8-V input voltage (one alkaline,
NiCd, or NiMH battery).
ACTUAL SIZE
3,05 mm x 4,98 mm
Only five small 1-µF ceramic capacitors are required to build a complete high efficiency dc/dc charge pump
converter. To achieve the high efficiency over a wide input voltage range, the charge pump automatically selects
between a 3x or 4x conversion mode.
typical application circuit
C1F
C2F
1 µF
1 µF
INPUT
0.9 V to 1.8 V
CIN
1 µF
OFF/ON
24 87
C1– C1+ C2– C2+
3
+
VIN
OUT1 5
2× IN
+
Max 40 mA
C(OUT1)
1
EN
TPS60300
OUT2
6
GND
PG 10
1 µF
3.3 V ±4%
+
Max 20 mA
R
C(OUT2)
1 µF
9
ALKALINE BATTERY OPERATING TIME
1.6
100
1.5
Efficiency
90
1.4
80
1.3
70
1.2
V Battery
60
1.1
50
1
40
0.9
30
0.8
20
0.7
10
0.6
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 340
Operating Time
Operating time (hours) with an alkaline battery
(2000 mAh) until power good goes low @ lL = 20 mA
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright  2001, Texas Instruments Incorporated
1