English
Language : 

LT10.7MS2 Datasheet, PDF (4/8 Pages) Tiger Electronic Co.,Ltd – This specification shall cover the characteristics of the ceramic
6 PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
No
Item
6.1 Humidity
High
Condition of Test
Subject the filter at (60 ± 2) ℃ and
90%~95% R.H. for 100 hours, filter shall be
measured after being placed in natural
conditions for 1 hour.
Subject the filter to (85 ± 5) ℃ for 100
Performance
Requirements
It shall fulfill the
specifications in
Table 1.
It shall fulfill the
6.2 Temperature hours, filter shall be measured after being specifications in
Exposure
Low
placed in natural conditions for 1 hour.
Table 1.
Subject the filter to (–-40±5)℃ for 100 hours, It shall fulfill the
6.3 Temperature filter shall be measured after being placed in specifications in
Exposure
natural conditions for 1 hour.
Table 1.
After temperature cycling of blow table was
performed 5 times, filter shall be measured after
6.4 Thermal
shock
being placed in natural conditions for 1 hour.
Temperature
Time
1 (–40±3)℃ (30±3) mins
2 Room temp.
5S
3 (+85±3)℃ (30±3) mins
It shall fulfill the
specifications in
Table 1.
4 Room temp.
5S
Subject the filter to vibration for 2 hours
each in x y and z axis with the amplitude of It shall fulfill the
6.5 Vibration
1.5mm, the frequency shall be varied specifications in
uniformly between the limits of 10Hz~55Hz Table 1.
and then filter shall be measured.
No visible damage
Apply the half-sine shock pulses:
6.6 Mechanical 981m/s2,6ms for 3 times in each direction of and it shall fulfill
Shock test
the specifications
three mutually perpendicular planes.
in Table 1.
6.7 Drop test
Filter shall be measured after 3 times
random dropping from the height of 1m on
concrete floor.
No visible damage
and it shall fulfill
the specifications
in Table 1.
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD.
4