78M6612 Datasheet, PDF (35/111 Pages) Teridian Semiconductor Corporation – Single-Phase, Dual-Outlet Power and Energy Measurement IC
DS_6612_001
78M6612 Data Sheet
IE0 through IEX6 are cleared automatically when the hardware vectors to the interrupt handler. The
other flags, IE_XFER through IE_WAKE, are cleared by writing a zero to them. Since these bits are in a
bit-addressable SFR byte, common practice would be to clear them with a bit operation. This is to be
avoided. The hardware implements bit operations as a byte wide read-modify-write hardware macro. If
an interrupt occurs after the read, but before the write, its flag will be cleared unintentionally. The proper
way to clear the flag bits is to write a byte mask consisting of all ones except for a zero in the location of
the bit to be cleared. The flag bits are configured in hardware to ignore ones written to them.
Table 31: Interrupt Enable and Flag Bits
Interrupt Enable
Name
Location
EX0
SFR A8[[0]
EX1
SFR A8[2]
EX2
SFR B8[1]
EX3
SFR B8[2]
EX4
SFR B8[3]
EX5
SFR B8[4]
EX6
SFR B8[5]
EX_XFER
2002[0]
EX_RTC
2002[1]
EX_FWCOL
2007[4]
EX_PLL
2007[5]
Interrupt Flag
Name
Location
IE0
SFR 88[1]
IE1
SFR 88[3]
IEX2
SFR C0[1]
IEX3
SFR C0[2]
IEX4
SFR C0[3]
IEX5
SFR C0[4]
IEX6
SFR C0[5]
IE_XFER
SFR E8[0]
IE_RTC
SFR E8[1]
IE_FWCOL0 SFR E8[3]
IE_FWCOL1 SFR E8[2]
IE_PLLRISE
SFRE8[6]
IE_PLLFALL SFRE8[7]
IE_WAKE
SFRE8[5]
Interrupt Description
External interrupt 0
External interrupt 1
External interrupt 2
External interrupt 3
External interrupt 4
External interrupt 5
External interrupt 6
XFER_BUSY interrupt (int 6)
RTC_1SEC interrupt (int 6)
FWCOL0 interrupt (int 2)
FWCOL1 interrupt (int 2)
PLL_OK rise interrupt (int 4)
PLL_OK fall interrupt (int 4)
AUTOWAKE flag
The AUTOWAKE flag bit is shown in Table 31 because it behaves similarly to interrupt flags, even though
it is not actually related to an interrupt. This bit is set by hardware when the MPU wakes from a rising
edge on wake timer timeout. The bit is reset by writing a zero.
Each interrupt has its own flag bit, which is set by the interrupt hardware and is reset automatically by the
MPU interrupt handler (0 through 5). XFER_BUSY and RTC_1SEC, which are OR-ed together, have
their own enable and flag bits in addition to the interrupt 6 enable and flag bits (see Table 31), and these
interrupts must be cleared by the MPU software.
When servicing the XFER_BUSY and RTC_1SEC interrupts, special care must be taken to
avoid lock-up conditions: If, for example, the XFER_BUSY interrupt is serviced, control must
not return to the main program without checking the RTC_1SEC flag. If this rule is ignored, a
RTC_1SEC interrupt appearing during the XFER_BUSY service routine will disable the
processing of any XFER_BUSY or RTC_1SEC interrupt, since both interrupts are edge-triggered.
The external interrupts are connected as shown in Table 31. The polarity of interrupts 2 and 3 is
programmable in the MPU via the I3FR and I2FR bits in T2CON. Interrupts 2 and 3 should be
programmed for falling sensitivity. The generic 8051 MPU literature states that interrupts 4 through 6 are
defined as rising edge sensitive. Thus, the hardware signals attached to interrupts 5 and 6 are inverted
to achieve the edge polarity shown in Table 31.
Rev. 1.2
35