Applications
In contrast to simple speed controller, the circuits shown
in figures 15 and 16, react to the load dependent speed
drop in which the magnitude of the load current acts on
the speed compensation.
For this purpose, the load current is measured by shunt
resistor R8. The voltage drop generates a current at Pin 11
dependent of R5, which reflects in the specified current at
the output of Pin 12.
Rated impedance of the output current at Pin 12 is repre-
sented through the coupling resistance R7 and the total
impedance of the set point.
The integrated load current proportional signal at C3
effects in the same direction on the control input as the set
point i.e., by the increase of load current follows an auto-
matic increase of manipulated set point, so that a
compensation of speed falls.
W W W Compensation arrangement is influenced with resistance
values i.e. R5 (= 100 to 5 k ) and R7 (= 10 k to 150 k )
whereas the higher effect is achieved by increasing the
value of R7 and decreasing R5. Influence of compensation
can be increased up to the value where the drive system
(motor) starts to oscillate.
Dimensioning in the applications are with the drill
machine of 700 W power.
L
230 V~
N
R6
4.7 kW
WR3
220 k
220 nF R7
C3 22 kW
C4
T1
BC308B
min
W R15
10 k
max
M
D1
1N4004
15 mF
10 V
R10
100 kW
14 13 12 11 10 9
8
18 kRW1
1.5 W
2R5kW
U210B
1
2
3
4
5
6
7
R4
BTA
470 kW
12–800
R12
100 W
50 mRW8
C1
22 mF
25 V
R2
220 kW
C2
10 nF
Figure 15. Speed control with load current compensation