U6049B Datasheet, PDF (4/8 Pages) TEMIC Semiconductors – Radiator Fan Controlled Timer
U6049B
VBatt
Ignition
Sth
closed
open
Pin 3
Pin 4
Delay time
(internal)
Relay
Pin 5=Vstab:
Relay
Pin 5 = GND:
Pin 5 = Programming Pin
Pin 2
Pin 2
94 8817
S = td
td is stopped, if Sth is open
Figure 7. Timing waveform
The programming input (Pin 5) is high-ohmic and should
therefore be connected to Pin 7 (Vstab) or GND. The relay
control output is shown according to Pin 5 connection.
Thermal switch input, Pin 4, is debounced (see figure 1).
Relay control output, Pin 2, is disabled when the battery
voltage, VBatt, is applied. Relay control output follows the
conditions of the switch, Sth, only when the ignition is
switched-ON. This is possible only after the debounce
time, t3. In this case Pin 5 is connected to Pin 7.
Timing waveforms are shown in figure 4. Total delay
time, td, is the sum of all ON-pulses caused by the thermo-
static switching. This can run down at once or in parts. If
Sth (Pin 4) is open, the oscillator is stopped (switched-off)
internally, but when it starts (Sth closed), the delay time,
td, starts running again. In case of renewed switching of
ignition, the counter of the delay time is reset.
VBatt
510 W
R1
200 kW 100 nF
R2
C2
8
7
6
5
C1
47 mF
U6049B
R5
94 8812
1
2
3
4
C3
R4
100 nF
20 kW R3
Terminal 15
Figure 8. R4 = 2 kW to 200 kW
Basic circuit
2 kW
Sth
Thermal
switch
4 (8)
TELEFUNKEN Semiconductors
Rev. A3, 04-Feb-97