U6046B / U6047B
Relay Control Output Behavior, Pin 2
Time functions (relay output) can be started or interrupted
by the three inputs i.e., ON, OFF or TOGGLE (Pins 3, 4
and 5).
The relay becomes active if the time function is triggered,
and the relay contact is interrupted after the elapse of
delay time, td. There are two input possibilities:
Toggle Input, Figures 5 and 6
When the push-button (TOGGLE) switch, S1, is pressed
for the first time, the relay becomes active after the
debounce time, t3, i.e., the relay output, Pin 2, is active.
Renewed operation of S1 causes the interruption of the
relay contact and the relay is disabled. Each operation of
the toggle switch, S1, changes (alters) the condition of the
relay output when the debounce time, t3, is exceeded i.e.,
the TOGGLE function.
If the relay output is not disabled by pressing the switch
S1, the output is active until the delay time, td, is over.
ON, OFF Inputs, Pins 3 and 4,
Figures 7 and 8
To avoid simultaneous operation of both inputs, Pin 3
(ON) and Pin 4 (OFF), use of two-way contact with
centre-off position with spring returns (also known as
rocker-actuated switch) is recommended.
Pressing the push-button switch (Pin 3-ON) leads to the
activation of the relay after the debounce time, t3,
whereas the switching of the Pin 4 switch correspond-
ingly leads to the relay being de-energized. If the relay is
not de-energized by the push-button switch, it becomes
disabled after the delay time, td, is over.
Combined operation, “TOGGLE and ON/OFF” is not
possible due to the fact that there is only one debouncing
circuit. Debouncing functions on both sides i.e., when-
ever S1 is ON or OFF.
If Pin 3 (input ON) is continuously closed, the delay time,
td, still elapses and the relay is interrupted. This can be
used to generate a defined power-on-reset pulse to trigger,
for example, a delay time, td, when the battery voltage,
VBatt, is applied.
W Figure 10 shows the input circuit of U6046B. It has an
integrated pull-down resistance (20 k ), RF capacitor
(15 pF) and Z-diode (7 V). It reacts to voltages greater
than 2 V. The external protective resistor has a value of
W 20 k and the push-button switch, S, is connected to the
battery as shown in the diagram.
Contact current, I, is calculated as follows:
+ + W + + I
VBatt–VZ
R( 20 k )
where VBatt
12 V, VZ
7V
+ [ W I
(12–7) V
20 k
0.25 mA
W It can be increased by connecting a 5.6 k resistor from
the push-button switch to ground as shown in figure 18.
VBatt
R1 510 W
C1
R2
C2
20 kW
47 mF/
16 V 8
7
6
5
S3
20 kW
U6046B
1
2
3
4
94 8753
Figure 7. ON/OFF function U6046B
VBatt
R1 510 W
C2
C1
R2
47 mF/
16 V 8
7
6
5
U6047B
1
2
3
4
2 kW
2 kW
S3
94 8754
Figure 8. ON/OFF function U6047B