English
Language : 

ROX2525T5 Datasheet, PDF (1/2 Pages) TEMEX – The ROX2525T5 OCXO presents interesting stability performance versus price
DISCRETE OCXO | STANDARD OCXO
ROX2525T5 (Not Recommended for New Designs)
The ROX2525T5 OCXO presents interesting stability performance versus price. Frequencies available are from 10MHz to 65MHz, and power
supply options are 3.3V, 5V & 12V. These 25 x 25 mm package series of oscillators are designed with direct heating on a single board. For
new designs, ROX2522S4 is recommended.
Features
 Small form factor
 Hold over below 25 µs over 24 hours
 Standard frequencies: 10, 12.8, 13, 20, 26
and 40 MHz
 2 packages height : 11.5 and 12.7 mm
Applications
 IEEE 1588: G.8263, G.8273.x
 Sync E modules
 Stratum 3E timing modules
 Time and frequency references
 Tests equipment
25.4 x 25.4 mm
Standard Specifications
Parameter
Min.
Nominal frequency
Operating temperature range
-40
Frequency stability over temperature ±5
Free-run accuracy over 20 years
Supply voltage stability
24 hours holdover performance
Hysteresis effect
Long term stability (Ageing)
Short term 1s to 10s integration time
Retrace effect at 25°C
Supply voltage (VCC)
Power consumption
Warm-up time
Harmonics (Sinewave)
Start-up time
Oscillator output - Sinewave
2
Oscillator output – Compatible CMOS
Output voltage level high (VOH) 2.4
Output voltage level low (VOL)
Rise & fall time
Environmental
Vibration
Shocks (3 directions)
Storage temperature
-55
Typ.
10 - 65
5
7
Max.
85
±10
±1
±2
±25
0.3
±0.5
±15
±75
0.01
±5
3
1
5
-35
0.25
9
0.4
5
10
50
90
Unit
MHz
°C
ppb
ppm
ppb
µs
ppb
ppb/day
ppb/month
ppb/year
ppb
ppb
V
W
W
minutes
dBc
sec
dBm
Test Condition / Description
Standard frequencies: 10, 12.8, 13, 20, 24.576,
26 and 40MHz
Calm air
Telcordia GR-1244 requirement is ± 4.6 ppm
±5% at 25°C
Temperature variation ± 2.8°C
After 1 week operation
After 24 hours off and 1 hour on
±5%. Standard options 3.3V and 12V
During warm-up
Steady state at 25°C calm air
Within 10 ppb of prior steady state output
frequency at time of power-off. 24 hours on min.
+ 24 hours off max.
Signal level with 50 Ω load
V
V
ns
g
IEC 68-2-06 test Fc-Severity 500/10
g
IEC 68–2-27 test Ea severity 50A
°C
www.rakon.com
www.rakon.com
Page 1 of 2