J421D-26M Datasheet, PDF (3/6 Pages) Teledyne Technologies Incorporated – MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS
SERIES 421
OUTLINE DIMENSIONS
CASE DETAIL
.370
(9.40)
DIA. MAX.
.335
(8.51)
DIA. MAX.
.280 (7.11) MAX.
TERMINAL LOCATIONS AND PIN NUMBERING (REF. ONLY)
(Viewed from Terminals)
.031 (.79)
±.003 (0.08)
.035 (.89)
±.010 (0.25)
36° ±3°
TYP.
9
1
8
2
WIRE LEAD: .75 (19.05) MIN.
PIN: .187 (4.75) ±.010 (.25)
(See Note 6)
.200 (5.08)
±.010 (.25) DIA.
7
6
4
+.002 (.05)
.017 (.43) –.001 (.03) DIA.
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 µsec or transfer in excess of 1
µsec.
2. “Typical” characteristics are based on available data and are best estimates. No
on-going verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series diode, 421DD only.
5. Unless otherwise specified, relays will be supplied with either gold-plated or solder-
coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Screened HI-REL versions available. Contact factory.
8.
SCHEMATIC DIAGRAMS
COIL B
COIL A
421
COIL B
421D
COIL A
COIL B
421DD
COIL A
SCHEMATICS ARE VIEWED FROM TERMINALS
COIL A LAST ENERGIZED
Teledyne Part Numbering System for T2R® Established Reliability Relay
ER 421 X M3 - 26 A / S Q
Established Reliability
Designator
Relay Series
Optional Ground Pin
(See Appendix)
Pad Option
(See Appendix)
Q= Solder Coated Leads
G= Gold Plated Leads
(Notes 5 and 6)
S= 0.187" leads
(Note 6)
Screening and Reliability
Level
Teledyne Part Numbering System for Military Qualified (JAN) Relays
J 421 X M - 26 P L
Coil Voltage
Military (JAN)
Designator
Relay Series
Optional Ground Pin
(See Appendix)
Pad Option
(See Appendix)
Screening and Reliability
Level
Terminal Variant
P = 0.187"
Coil Voltage
JAN part number example is for reference only. Actual part number may not exist.
421 Page 3
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2005 TELEDYNE RELAYS