English
Language : 

J412D-6WM Datasheet, PDF (3/6 Pages) Teledyne Technologies Incorporated – ESTABLISHED RELIABILITY TO-5 RELAYS
SERIES 412
OUTLINE DIMENSIONS
.370
(9.40)
DIA. MAX.
.335
(8.51)
DIA. MAX.
.270 (6.86) MAX.
TERMINAL LOCATIONS AND PIN NUMBERING (REF. ONLY)
(Viewed from Terminals)
.035 (.89)
± .010 (0.25)
.031 (.79)
± .003 (0.08)
TRANSISTOR BASE
CONNECTION FOR
412T ONLY
9
8
10
1
2
7
3
WIRE LEAD: .75 (19.05) MIN.
PIN: .187 (4.75) ±.010 (.25)
(See Note 6)
+.002 (.05)
.017 (.43) –.001 (.03) DIA.
.200 (5.08)
± .010 (.25) DIA.
36° ±3°
TYP.
6
4
5
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
SCHEMATIC DIAGRAMS
412
412DD
412D
412T
SCHEMATICS ARE VIEWED
FROM TERMINALS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of
1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No
on-going verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due
to internal series semiconductor. 412DD and 412T only.
5. Unless otherwise specified, relays will be supplied with either gold-plated or
solder-coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Limit Base Emitter current to 15 mAdc.
8. Applicable to all coil voltages. See Base current to turn on.
9. Screened HI-REL versions available. Contact factory.
10.
TYPICAL LOGIC INTERFACE
(See Note 8)
Vcc
Vr
Pin 1
Logic element
1 = 0.50 to 3.00mA
0 = 0.3Vdc min.
Pin 10
Pin 9
Notes:
Logic 1 activates the relay.
Logic 0 de-activates the relay.
Vcc = logic bias power.
Vr = coil energization voltage.
Teledyne Part Numbering System for T2R® Established Reliability Relay
ER 412 Y M - 26 A / S Q
Established Reliability
Designator
Relay Series
Optional Ground Pin
(See Appendix)
Pad Option
(See Appendix)
Q= Solder-Coated Leads
G= Gold-Plated Leads
(Notes 5 and 6)
S= .187" leads
(Note 6)
Screening and Reliability
Level
Coil Voltage
Military (JAN)
Designator
Relay Series
Optional Ground Pin
(See Appendix)
Spreader Option
(See Appendix)
Teledyne Part Numbering System for Military Qualified (JAN) Relays
J 412 Y M - 26 P L
Screening and Reliability
Level
Terminal Variant
P = 0.187"
Coil Voltage
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
412 Page 3
412/1203/Q1