English
Language : 

J411-12PM Datasheet, PDF (3/6 Pages) Teledyne Technologies Incorporated – ESTABLISHED RELIABILITY TO-5 RELAYS
SERIES 411
OUTLINE DIMENSIONS
CASE DETAIL
.370
(9.40)
DIA. MAX.
.335
(8.51)
DIA. MAX.
.035 (.89)
± .010 (0.25)
LEAD & PIN LOCATIONS
(Viewed from Terminals)
.031 (.79)
± .003 (0.08)
.200 (5.08)
± .010 (.25) DIA.
.270 (6.86) MAX.
WIRE LEAD: .75 (19.05) MIN.
PIN: .187 (4.75) ±.010 (.25)
(See Note 6)
+.002 (.05)
.017 (.43) ±.001 (.03) DIA.
45° ±3°
TYP.
5 LEADS
36° ±3°
TYP.
411, 411D, 411DD
8 LEADS
411T
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
PIN NUMBERS
(For reference only)
9
1
8
2
7
3
6
4
411T
4
1
5
3
2
411, 411D, 411DD
SCHEMATIC DIAGRAMS
411
411DD
411T
411D
SCHEMATICS ARE VIEWED FROM TERMINALS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of
1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No
on-going verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due
to internal series semiconductor, 411DD and 411T only.
5. Unless otherwise specified, relays will be supplied with either gold-plated or
solder-coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Limit Base Emitter current to 15 mAdc.
8. Applicable to all coil voltages. See Base current to turn on.
9. Screened HI-REL versions available. Contact factory.
10.
TYPICAL LOGIC INTERFACE
(See Note 8)
Vcc
Vr
Pin 1
Logic element
1 = 0.40 to 2.38mA
0 = 0.3Vdc min.
Pin 4
Pin 2
Pin 3
Notes:
Logic 1 activates the relay.
Logic 0 de-activates the relay.
Vcc = logic bias power.
Vr = coil energization voltage.
Established Reliability
Designator
Relay Series
Optional Ground Pin
(See Appendix)
Pad Option
(See Appendix)
Military (JAN)
Designator
Relay Series
Pad Option
(See Appendix)
Teledyne Part Numbering System for T2R® Established Reliability Relay
ER 411 Y M3 - 26 A / S Q
Teledyne Part Numbering System for Military Qualified (JAN) Relays
J 411 M3 - 26 P L
Q= Solder Coated Leads
G= Gold Plated Leads
(Notes 5 and 6)
S= .187" leads
(Note 6)
Screening and Reliability
Level
Coil Voltage
Screening and Reliability
Level
Terminal Variant
P = 0.187"
Coil Voltage
411 Page 3
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
411/1203/Q1