English
Language : 

X24D12 Datasheet, PDF (2/3 Pages) Teledyne Technologies Incorporated – Output to 16A 280 Vac DC Control
INPUT (CONTROL) SPECIFICATION
Min
Max Units
Control Range
7
30 Vdc
Input Current Range
5
30 mAdc
Must Turn-Off Voltage
1
Vdc
Input Resistance (Typical)
1000 Ohms
Reverse Voltage Protection
30
V
OUTPUT (LOAD) SPECIFICATION
Min
Max
Operating Range
12
280
Peak Voltage
600
Units
Vrms
Vpeak
Load Current Range (Resistive)
X24D12
.005
X24D16
.005
*Terminals limited at 16A
12 Arms
25* Arms
Maximum Surge Current Rating (Non-Repetitive)
X24D12
120
A
X24D16
250
A
On-State Voltage Drop
Zero-Cross Window (Typical)
Off-State Leakage Current (60Hz)
Turn-On Time (60 Hz)
Turn-Off Time (60 Hz)
Off-State dv/dt
Maximum di/dt (Non-Repetitive)
Operating Frequency Range 0.1
1.3
V
±12 Vac
1
mA
8.3
ms
8.3
ms
500 V/µs
50
A2s
440 Hz
I2t for Match Fusing (<8.3ms)
X24D12
.005
X24D16
.005
72
A2S
310 A2S
ENVIRONMENTAL SPECIFICATION
Min
Max
Operating Temperature
–40
100
Storage Temperature
–40
100
Input-Output Isolation
4000
Output-Case Isolation
2500
Units
°C
°C
Vrms
Vrms
Series X
CONTROL CHARACTERISTIC
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Control Voltage (V)
Figure 4 — X relays
SURGE CURRENT
150
100
Non-Repetitive
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Figure 5a — X24D12 relay
250
200
150
Non-Repetitive
100
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Figure 5b — X24D16 relay
X2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
X\032003\Q1