English
Language : 

TS24D2G Datasheet, PDF (2/4 Pages) Teledyne Technologies Incorporated – Output to 2.5A, 275 Vac AC/DC Control
L1
N
BLOCK DIAGRAM
A1
A2
Figure 3a — TS24D2G
grid 0.1"
bottom view
A1
NO
A2
C
A1
A2
Figure 3b — TS3R1G
GRID DIAGRAM
grid 0.1"
bottom view
A1
NO
A2
C
Series TS
+
A1
A2
Load
(*)
(*) On inductive load
–
Figure 3c — TS3R2G
grid 0.1"
bottom view
A1
NO
C
A2
Figure 4a — TS24D2G
Figure 4b — TS3R1G
Figure 4c — TS3R2G
OUTPUT (LOAD) SPECIFICATION
Min
Max Unit
Operating Range
TS24D2G
12
275 Vrms
TS3R2G
0
30 Vdc
TS3R1G
0
30 Vac/Vdc
OUTPUT (LOAD) SPECIFICATION (Continued)
Min
Max Unit
On-State Voltage Drop
TS24D2G
1.0
V
TS3R2G
0.5
V
TS3R1G
0.9
V
Peak Voltage
TS24D2G
TS3R2G
TS3R1G
600
V
60
V
60
V
Zero-Cross Window (Typical)
TS24D2G
TS3R2G
TS3R1G
±10
V
NA
NA
Load Current Range
TS24D2G
TS3R2G
TS3R1G
.05
2 Arms
.001
2.5 Arms
.001
1 Arms
Maximum Surge Current Rating (Non-Repetitive)
(See Figure 6)
TS24D2G
100
A
TS3R2G
12
A
TS3R1G
2.4
A
Off-State Leakage Current (60Hz)
All relays
Operating Frequency Range
TS24D2G
1
TS3R1G
0
Turn-On Time (60Hz)
TS24D2G
TS3R2G
TS3R1G
1
mA
440 Hz
50 KHz
10
ms
50
µs
5
ms
TS 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
TS\032003\Q1