English
Language : 

J134D-5M Datasheet, PDF (2/6 Pages) Teledyne Technologies Incorporated – CENTIGRID ESTABLISHED RELIABILITY RELAYS
SERIES 134
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Resistive:
Inductive:
Lamp:
Low Level:
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 μA/10 to 50mV
Resistive:
250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
2A/28Vdc Resistive (100 cycles min.)
Contact factory
200 milliwatts typical at nominal rated voltage @ 25°C
4.0 msec max. at nominal rated coil voltage
134 Series: 2.0 msec max. 134D, 134DD Series: 7.5 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
70,000 ft.: 125 Vrms/60Hz
134D, 134DD
1.0 max
134D, 134DD
100 min.
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
BASE PART
NUMBERS
(See Note 8 for full P/N example)
Coil Voltage (Vdc)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(134DD Series)
Pick-up Voltage (Vdc, Max.)
Drop-out Voltage (Vdc)
Nom.
Max.
134, 134D
134DD (Note 4)
Min.
Max.
134, 134D
134DD
134, 134D
Min.
Max.
134DD
Min.
Max.
134-5
134D-5
134DD-5
5.0
7.5
100
64
56.8
78.1
3.5
3.7
0.12
2.5
0.7
2.6
134-6
134D-6
134DD-6
6.0
10.0
200
125
36.3
48.9
4.5
4.8
0.18
3.2
0.8
3.0
134-9
134-12 134-18 134-26
134D-9 134D-12 134D-18 134D-26
134DD-9 134DD-12 134DD-18 134DD-26
9.0
12.0
18.0
26.5
15.0
20.0
30.0
40.0
400
800
1600
3200
400
800
1600
3200
18.1
12.5
9.6
7.2
23.6
16.0
12.2
9.0
6.8
9.0
13.5
18.0
8.0
11.0
14.5
19.0
0.35
0.41
0.59
0.89
4.9
6.5
10.0
13.0
0.9
1.0
1.1
1.3
4.5
5.8
9.0
13.0
PERFORMANCE CURVES
(NOTE 2)
TYPICAL RF PERFORMANCE
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01
INSERTION LOSS
IRSOETLAUTIRSIONONLLAOATSCIOSRNO(VSASSCWRCROO)SNSTAPCOTLSES
1.92
1.22
1.07
1.02
1.01
1.00
0.5 .1
1.00
.5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL DC CONTACT RATING (RESISTIVE)
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
134 Page 2
134/1203/Q1