English
Language : 

DRD48A20 Datasheet, PDF (2/3 Pages) Teledyne Technologies Incorporated – Dual Output to 25A 510 Vac DIN-Rail Solid-State Relay
Series DRD
INPUT (CONTROL) SPECIFICATION
Min
Max Units
Control Range
DRD48A20
150
240 Vac/dc
All others
3.5
32 Vdc
Control Current Range
DRD48A20
3
7
mA
All others
8.5
10 mAdc
Must Turn-Off Voltage
DRD48A20
15
V
All others
2
V
Reverse Voltage (DC control)
32
V
Clamping Voltage (DC control)
42
V
Input LED
Green
OUTPUT (LOAD) SPECIFICATION
Min
Max Unit
Operating Range
24
510 Vrms
Peak Voltage
1200 Vpeak
Clamping Voltage (@ 1mA)
820
V
Load Current Range (See Figure 4)
DRD48D25
.005
25 Arms
All others
.005
20 Arms
Zero-Cross Window
±20
V
Non-Repetitive Overload Current (See Figure 5)
DRD48D25
1000 A
All others
550
A
On-State Voltage Drop
0.9
V
Output Power Dissipation
(Typical): each phase
0.8xI+0.08xI2
W
Thermal Resistance Junction to Air
DRD48D25
2.1 °C/W
All others
2.2 °C/W
Off-State Leakage Current (60Hz)
1
mA
Turn-On Time (60Hz)
DRD48DXX
8.3
ms
DRD48RXX
0.1
ms
DRD48AXX
25
ms
Turn-Off Time (60Hz)
8.3
ms
DRD48AXX
25
ms
All others
8.3
ms
THERMAL CHARACTERISTICS
30
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (°C)
Figure 4a — DRD48X20
30
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (°C)
Figure 4b — DRD48D25
SURGE CURRENTS
600
Non-Repetitive
400
200
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5a — DRD48X20
1500
1000
Non-Repetitive
500
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5b — DRD48D25
DRD 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
DRD\032003\Q1