English
Language : 

AP308 Datasheet, PDF (2/2 Pages) Teledyne Technologies Incorporated – 10 TO 250 MHz TO-8 CASCADABLE AMPLIFIER
TYPICAL PERFORMANCE
KEY: +25 °C
+85 °C
Gain vs Temperature Vcc = 8
-55 °C
14.0
13.0
12.0
11.0
5 10 30 50 100
150
200
250
FREQUENCY - MHz
300
350
Noise Figure
5.0
+8 V
4.0
3.0
+5 V
2.0
10 20 30 50 100
150
200
250
300
350
FREQUENCY - MHz
Power Output at 1 dB Compression
24.0
23.0
+8 V
22.0
21.0
20.0
+5 V
19.0
18.0
17.0
10 20 30 50 100
150
200
250
FREQUENCY - MHz
300
350
Intercept Point Vcc = 8
70
60
50
IP2
40
2nd HAR
30
IP3
20
10 20 30 50 100
150
200
250
FREQUENCY - MHz
300
350
Intercept Point Vcc = 5
70
60
50
IP2
40
2nd HAR
30
IP3
20
10 20 30 50 100
150
200
250
FREQUENCY - MHz
300
350
AP308
TYPICAL AUTOMATIC TEST DATA
Model: AP308
FREQ SWR SWR
MHZ
IN
OUT
5
1.28
1.14
10
1.23
1.11
30
1.20
1.09
50
1.20
1.09
100
1.19
1.09
150
1.20
1.07
200
1.26
1.06
250
1.38
1.09
300
1.56
1.16
350
1.83
1.28
Model: AP308
FREQ
MHz
5
10
30
50
100
150
200
250
300
350
S11
MAG ANG
0.12 -109.1
0.10 -136.8
0.09 -165.4
0.09 -172.8
0.09 -174.9
0.09 -168.6
0.12 -161.4
0.16 -160.0
0.22 -164.6
0.29 -174.0
Model: AP308
FREQ SWR SWR
MHZ
IN
OUT
5
1.27
1.17
10
1.21
1.11
30
1.19
1.08
50
1.20
1.07
100
1.22
1.07
150
1.28
1.07
200
1.40
1.11
250
1.60
1.20
300
1.87
1.32
350
2.25
1.49
Model: AP308
FREQ
MHz
5
10
30
50
100
150
200
250
300
350
S11
MAG ANG
0.12 -104.2
0.10 -132.6
0.09 -159.7
0.09 -162.7
0.10 -158.9
0.12 -154.4
0.17 -154.5
0.23 -159.6
0.30 -168.5
0.38 179.9
Vcc=+8V
GAIN
PHASE
DB
DEG
12.97
-169
13.25
-175
13.35
175
13.32
169
13.24
157
13.19
145
13.15
133
13.11
121
13.03
108
12.86
95
GROUP DELAY
NSEC
0.99
0.77
0.67
0.66
0.66
0.68
0.71
0.73
Icc=92.43
REV/ISO
DB
-18.3
-17.6
-17.4
-17.4
-17.3
-17.2
-17.1
-16.9
-16.8
-16.7
LINEAR S-PARAMETERS
Vcc=+8V
S21
S12
MAG ANG MAG ANG
4.45 -168.9 0.122 -174.0
4.60 -175.4 0.132 -177.8
4.65 175.0 0.135 173.9
4.63 169.3 0.136 167.4
4.59 157.0 0.137 153.3
4.57 145.2 0.138 139.9
4.54 133.4 0.140 127.1
4.52 121.2 0.143 114.0
4.48 108.5 0.145 101.2
4.40 95.3 0.147 89.1
Icc=92.43
S22
MAG ANG
0.07 -67.1
0.05 -119.2
0.04 -172.0
0.04 171.5
0.04 146.2
0.04 133.8
0.03 142.0
0.04 167.3
0.08 177.4
0.12 172.6
Vcc=+5V
GAIN
PHASE
DB
DEG
12.73
-168
13.14
-176
13.26
174
13.23
168
13.13
155
13.06
142
12.97
129
12.85
116
12.65
102
12.33
88
GROUP DELAY
NSEC
1.10
0.82
0.71
0.71
0.72
0.74
0.76
0.78
Icc=55.20
REV/ISO
DB
-18.5
-17.7
-17.5
-17.5
-17.3
-17.2
-17.1
-16.9
-16.8
-16.8
LINEAR S-PARAMETERS
Vcc=+5V
S21
S12
MAG ANG MAG ANG
4.38 -169.5 0.122 -173.8
4.54 -175.7 0.130 -177.7
4.60 174.4 0.134 173.3
4.59 168.4 0.134 166.8
4.54 155.2 0.136 151.8
4.50 142.4 0.137 137.6
4.45 129.4 0.139 123.7
4.39 116.1 0.142 109.6
4.29 102.4 0.144 96.0
4.13 88.5 0.144 83.1
Icc=55.20
S22
MAG ANG
0.07 -65.3
0.05 -108.9
0.04 -159.0
0.04 -172.6
0.03 178.1
0.04 -173.4
0.05 -164.8
0.09 -168.0
0.14 -176.2
0.20 172.4
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com