English
Language : 

AC1291 Datasheet, PDF (2/2 Pages) Teledyne Technologies Incorporated – 30 TO 1400 MHz TO-8 CASCADABLE AMPLIFIERS
AC1291/AC1292
TYPICAL PERFORMANCE
TYPICAL AUTOMATIC TEST DATA
KEY: +25 °C
+85 °C
Gain vs Temperature AC1291
-55 °C
19.0
+5 V
18.0
17.0
16.0
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Gain vs Temperature AC1292
20.0
+5 V
19.0
18.0
17.0
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Noise Figure Vcc = 5
3.0
AC1292
2.0
AC1291
1.0
0.0
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Power Output at 1 dB Compression
28.0
26.0
AC1292 - 8 V
24.0
AC1291 - 8 V
AC1292 - 5 V
22.0
20.0
AC1291 - 5 V
18.0
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Intercept Point AC1291 Vcc = 5
70
60
2nd HAR
50
40
IP2
30
IP3
20
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Intercept Point AC1292 Vcc = 5
70
60
2nd HAR
50
40
IP2
30
IP3
20
0.03 0.1 0.2
0.4
0.6
0.8
1.0
1.2
1.4
FREQUENCY - GHz
Model: AC1291
FREQ SWR SWR
MHZ
IN
OUT
30
1.75
1.45
50
1.55
1.46
100
1.44
1.46
200
1.40
1.44
300
1.40
1.42
400
1.41
1.38
500
1.43
1.34
600
1.44
1.30
700
1.47
1.26
800
1.47
1.21
900
1.49
1.17
1000
1.50
1.13
1100
1.49
1.10
1200
1.48
1.07
1300
1.46
1.06
1400
1.42
1.07
1500
1.35
1.12
Model: AC1291
FREQ.
S11
MHz
MAG ANG
30
0.27 -35.50
50
0.22 -29.50
100
0.18 -19.80
200
0.17 -12.80
300
0.17 -10.50
400
0.17 -9.70
500
0.18 -10.40
600
0.18 -12.50
700
0.19 -15.40
800
0.19 -19.50
900
0.20 -25.00
1000
0.20 -30.60
1100
0.20 -37.70
1200
0.19 -45.30
1300
0.19 -53.90
1400
0.17 -63.50
1500
0.15 -75.00
Model: AC1292
FREQ SWR SWR
MHZ
IN
OUT
30
1.66
1.36
50
1.45
1.46
100
1.29
1.52
200
1.23
1.53
300
1.22
1.52
400
1.22
1.51
500
1.22
1.49
600
1.23
1.48
700
1.24
1.47
800
1.25
1.45
900
1.27
1.44
1000
1.28
1.42
1100
1.29
1.41
1200
1.31
1.40
1300
1.33
1.39
1400
1.34
1.39
1500
1.34
1.40
Model: AC1292
FREQ.
S11
MHz
MAG ANG
30
0.24 -39.90
50
0.18 -37.40
100
0.13 -26.60
200
0.11 -11.30
300
0.11 -2.30
400
0.12 3.30
500
0.13 4.70
600
0.14 5.50
700
0.15 4.60
800
0.15 1.30
900
0.17 -1.60
1000
0.17 -4.60
1100
0.18 -8.50
1200
0.18 -12.40
1300
0.18 -14.70
1400
0.18 -16.60
1500
0.16 -18.10
Vcc= +5V
GAIN
PHASE
DB
DEG
17.76
-163.0
18.10
-173.0
18.30
176.0
18.36
161.0
18.33
149.0
18.29
138.0
18.22
126.0
18.15
115.0
18.06
104.0
17.97
93.0
17.88
83.0
17.78
72.0
17.67
61.0
17.57
50.0
17.45
39.0
17.33
28.0
17.22
17.0
DELAY
NSEC
1.10
0.64
0.37
0.34
0.32
0.31
0.31
0.31
0.30
0.31
0.30
0.31
0.30
0.31
0.31
0.31
LINEAR S-PARAMETERS
Vcc= +5V
S21
S12
MAG ANG MAG ANG
7.73 -163.20 0.07 -1.90
8.03 -172.70 0.06 -3.20
8.22 175.80 0.06 -5.50
8.28 161.50 0.06 -8.50
8.25 149.30 0.06 -11.40
8.21 137.80 0.06 -14.60
8.14 126.50 0.06 -19.20
8.08 115.40 0.07 -23.60
8.00 104.40 0.07 -27.70
7.92 93.50
0.07 -32.50
7.83 82.50
0.07 -37.80
7.75 71.70
0.08 -42.80
7.64 60.70
0.08 -48.70
7.56 49.90
0.08 -54.00
7.46 38.90
0.08 -61.10
7.36 27.90
0.09 -67.40
7.26 16.80
0.09 -74.50
Icc= 63.60
REV/ISO
DB
-23.40
-24.00
-24.30
-24.20
-24.20
-24.00
-23.90
-23.50
-23.20
-22.90
-22.70
-22.30
-22.10
-21.80
-21.50
-21.30
-20.90
Icc= 63.60
S22
MAG ANG
0.19 -117.90
0.19 -143.70
0.19 -167.60
0.18 174.00
0.17 163.10
0.16 153.80
0.14 145.00
0.13 137.70
0.11 131.20
0.10 122.70
0.08 114.70
0.06 106.00
0.05 92.20
0.03 67.70
0.03 35.80
0.04 -1.50
0.06 -22.30
Vcc= +5V
GAIN
PHASE
DB
DEG
17.83
-164.0
18.34
-172.0
18.68
177.0
18.76
164.0
18.75
153.0
18.72
143.0
18.65
133.0
18.61
123.0
18.51
113.0
18.45
104.0
18.36
94.0
18.26
84.0
18.17
75.0
18.07
65.0
17.97
56.0
17.84
46.0
17.72
36.0
DELAY
NSEC
0.99
0.46
0.37
0.30
0.28
0.28
0.27
0.27
0.27
0.27
0.26
0.27
0.26
0.27
0.27
0.26
LINEAR S-PARAMETERS
Vcc= +15V
S21
S12
MAG ANG MAG ANG
7.75 -164.40 0.07 0.70
8.14 -172.80 0.07 -3.20
8.42 176.40 0.06 -5.20
8.48 162.80 0.06 -8.50
8.47 151.30 0.07 -11.60
8.43 140.60 0.07 -15.50
8.37 129.90 0.07 -19.50
8.30 119.50 0.07 -24.00
8.22 109.30 0.07 -28.20
8.15 99.00
0.07 -32.10
8.06 88.70
0.07 -36.60
7.97 79.00
0.07 -41.60
7.87 68.70
0.07 -46.90
7.80 58.80
0.08 -52.50
7.72 48.80
0.08 -57.70
7.64 38.70
0.08 -63.20
7.57 28.70
0.08 -68.60
Icc= 100.30
REV/ISO
DB
-23.10
-23.60
-24.10
-24.10
-24.00
-24.10
-23.90
-23.70
-23.60
-23.60
-23.40
-23.30
-23.10
-22.90
-22.80
-22.60
-22.30
Icc= 100.30
S22
MAG ANG
0.14 -125.30
0.17 -149.00
0.18 -171.60
0.19 168.90
0.18 155.90
0.18 144.50
0.17 133.50
0.17 123.20
0.16 112.90
0.15 101.40
0.15 90.90
0.14 80.90
0.14 69.70
0.14 59.50
0.13 49.10
0.14 38.60
0.14 28.90
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com