English
Language : 

XV46D30K Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – Single Output to 30A 420 Vac No Heat Sink, Hybrid Relay
Part Number
XV46D30K
Description
30A, 420 Vac
Part Number Explanation
XV
46
D
30
K
Series XV
Single Output to 30A 420 Vac
No Heat Sink, Hybrid Relay
NOTES
1) Line Voltage (nominal): 46 = 420 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: K = 20–30 Vdc, *C = 12 Vdc also available
MECHANICAL SPECIFICATION
M4
1.10 (28)
Ø.19 (Ø4.7)
WEIGHT: 5.64 oz (160g)
1.75 (44.5)
M3.5
1.00 (25.4)
Figure 1 – XV relay; dimensions in inches (mm)
INPUT (CONTROL) SPECIFICATION
Min
Max Units
Control Range*
20
30 Vdc
Input Current Range
31
41 mAdc
Must Turn-Off Voltage
10 Vdc
Input Resistance (Typical)
640 Ohms
Reverse Voltage Protection
30 Vdc
Control Frequency
1
Hz
TYPICAL APPLICATION
A1+
Vc
A1-
Supply
t3 t2
t1
LED
SSR
EMR
Figure 2 – XV relay
T1
VL
L1
Load
FEATURES/BENEFITS
• Industry standard package
• Combines the best of solid-state and
electromechanical relays
• Tight zero-cross window for low EMI
• Control LED
• Internal output protection
• High immunity to surges
DESCRIPTION
The Series XV relay combines the best of solid-state
and electromechanical technology. The relay is
designed in a touch-proof hockey-puck package. The
XV relay switches current up to 30A without a heat
sink. Visual control status is provided as a standard.
Elimination of the heat sink conserves space and
makes the XV ideal for numerous applications.
APPLICATIONS
• Interface applications
• Heating Control
• Light/Lamp control
• Contactor driver
• Fan speed control
• HVAC controls
APPROVALS
Model XV46D30K is UL recognized.
UL File Number: E128555.
CONTROL CHARACTERISTIC
45
40
35
30
25
20
15
10
5
0
0
5 10 15 20 25 30 35
Control Voltage (V)
Figure 3 – XV relay
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
XV 1
XV\032003\Q1