English
Language : 

S2CP20201 Datasheet, PDF (1/1 Pages) Teledyne Technologies Incorporated – NON REFLECTIVE SINGLE-POLE DOUBLE-THROW SWITCH
9/2010
DC TO 20 GHz
S2CP20201 NON REFLECTIVE SINGLE-POLE
DOUBLE-THROW SWITCH
Typical Values
S2CP20201
Low Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
<3.0 dB
High Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
>45 dB
High Output Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +22.0 dBm
High Third Order I.P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+XX dBm
2 Stage CougarPak™ for Switches
S2CP20201
2 Stage CougarPak™ for Switches
SPECIFICATIONS*
Parameter
Frequency (Min.)
Insertion Loss (Max.)
DC-500 MHz
500-18000 MHz
18000-20000 MHz
Isolation (Min.) DC-500 MHz
500-18000 MHz
18000-20000 MHz
SWR (Max.)^
Input/Output
DC-500 MHz
500-18000 MHz
18000-20000 MHz
Power Output (Min.)
@ 1dB comp. DC-500 MHz
500-18000 MHz
18000-20000 MHz
Switching Time†
DC-20 GHz
DC Current (Max.)
Typical
DC - 20 GHz
<1.5 dB
<2.2 dB
<3.0 dB
63 dB
45 dB
45 dB
<1.3:1
<1.3:1
<1.4:1
+22.0 dBm
+24.0 dBm
+22.0 dBm
75/50 ηsec
4 mA
Guaranteed*
0 to 50 °C -55 to +85 °C
DC - 20 GHz
DC - 20 GHz
1.8 dB
3.5 dB
3.8 dB
60.0 dB
42.0 dB
42.0 dB
2.0 dB
3.7 dB
4.0 dB
60.0 dB
42.0 dB
42.0 dB
1.9:1
1.9:1
1.9:1
2.0:1
2.0:1
2.0:1
+20.0 dBm
+22.0 dBm
+20.0 dBm
80/60 ηsec
5 mA
+19.0 dBm
+21.0 dBm
+19.0 dBm
80/60 ηsec
5 mA
* Measured in a 50-ohm system at –5 Vdc unless otherwise specified.
^ Insertion loss state. † 50% TTL control to 10% or 90% RF.
INTERMODULATION PERFORMANCE
Typical @ 25 °C, –5 Volts, and 1000 MHz
S2CP20201
Second Order Two Tone Intercept Point . . . . . . . . . . . . . . .
+XX dBm
Third Order Two Tone Intercept Point . . . . . . . . . . . . . . . . .
+XX dBm
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to +125 °C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+150 °C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –5.5 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+28 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . .
+31 dBm
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
+34 dBm
Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+125 °C
LOGIC TABLE
TTL
CONTROL J1-J2
J1-J3
LOW ISOLATION INSERTION
LOSS
HI INSERTION ISOLATION
LOSS
LOW is defined as 0 to +0.8 V
HI is defined as +2.4 V to +5.5 V
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com