LC3005 Datasheet, PDF (1/1 Pages) Teledyne Technologies Incorporated – 5 TO 3000 MHz TO-8 CASCADABLE LC3005 SIGNAL LIMITER
PRELIMINARY
LC3005
5 TO 3000 MHz
TO-8 CASCADABLE SIGNAL LIMITER
Typical Values
Low Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low VSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High CW Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Peak Power (2 µsec max.) . . . . . . . . . . . . . . . . . . . . . .
High Performance Thin Film
Standard Size TO-8 Package
LC3005
0.2 dB
1.2:1
1 Watt
75 Watt
LC3005
TO-8 Package for Limiter
SPECIFICATIONS*
Parameter
Frequency (Min.)
Insertion Loss (Max.)
10 - 1500 MHz
1500 - 3000 MHz
Typical
5-3200 MHz
0.2 dB
0.5 dB
Insertion Loss Flatness (Max.)
VSWR (Max.) Input/Output
Maximum Output
Limiting Level
@+30 dBm Input (dBm)
No DC Voltage Required
±0.5 dB
1.2:1
+15.0 dBm
Guaranteed
0 to 50° C -55 to +85° C
5-3000 MHz
5-3000 MHz
0.6 dB
1.0 dB
0.8 dB
1.2 dB
±0.8 dB
1.5:1
±1.0 dB
1.6:1
+16.0 dBm
+17.0 dBm
* Measured in a 50-ohm system. No DC voltage applied.
INTERMODULATION PERFORMANCE
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
Maximum Peak Power (2 µsec Max.) . . . . . . . . . . . . . . . . . .
-62 to 125° C
+125° C
1 Watt
50 Watt
75 Watt
LS3005
SMTO-8 Package for Limiters
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com