DTQ6001 Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – 0.1 TO 6.0 GHz THRESHOLD DETECTOR
Rev. 7/10
DTQ6001
0.1 TO 6.0 GHz
THRESHOLD DETECTOR
Typical Values @ +25 °C
Wide Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . .
Wide Power Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature Stability . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Flatness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cougar Q Package
DTQ6001
0.1 to 6.0 GHz
-30.0 to -5.0 dBm
± 0.50 dB
± 0.50 dB
DTQ6001
SM-25 for Detectors
SPECIFICATIONS*
Parameter
Frequency (Min.)
Input Power Range (Min.)
VSWR (Max.)
Power Flatness (Max.)
Threshold Temperature Stability
(Max.)
Threshold Hysteresis
Pulse Response
Logic: Pin > Pth
Output Voltage Hi @ 5mA source
Output Voltage Lo @ 5mA sink
Supply Current
Typical
0.1-7.0 GHz
-30 to -5 dBm*
1.5:1†
±0.5 dB
±0.25 dB^
±0.2 dB
15 µsec^‡
1
4.4 Volts
0.1 Volts
6.0 mA
Guaranteed
0 to 50 °C -55 to +85 °C
0.1-6.0 GHz
0.1-6.0 GHz
-25 to -5 dBm*
-25 to -5 dBm*
2.0:1†
±0.75 dB
2.0:1†
±0.75 dB
±0.5 dB^
±0.5 dB
50 µsec^‡
1
3.5 Volts
0.5 Volts
8.0 mA
±0.5 dB^
±0.5 dB
50 µsec^‡
1
3.5 Volts
0.5 Volts
8.0 mA
* Measured in a 50 Ohm system at Vs=+5.0 Vdc. Rth = 10 to 100 KOhm. ^ Rth = 100 to 20 KOhm.
† Pin ≤–15 dBm. ‡ 50% RF to 10 or 90% Video Response time for input change ≥3 dB above Pth.
MAXIMUM RATINGS
DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+5 V
Continuous RF Input Power . . . . . . . . . . . . . . . . . . . . .
+14.0 dBm
Operating Case Temperature . . . . . . . . . . . . . . . . . . . . -55 °C to +100 °C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 °C to +125 °C
Burn-In Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .
+100 °C
Detector Thermal Resistance1 (θjc) . . . . . . . . . . . . . . .
+3500 °C/Watt
Temperature Rise @ 0 dBm . . . . . . . . . . . . . . . . . . . . .
+3.5 °C
1 Thermal resistance is based on RF input power. Ratings based on +25 °C.
APPLICATION NOTES
This unit is DC coupled and employs a RF choke at the input (DC short).
DO NOT bypass the Threshold Control pin. Capacitance greater than 50pF may cause
instabilities. Keep the threshold programming resistor or circuit close to this pin.
Average power detection is obtained at power levels below approximately –13 dBm.
The output of this unit is derived from an op-amp, not a true logic device.
Connect external threshold resistor from Rcntl port to ground.
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com