English
Language : 

DTC4001 Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – 0.01 TO 4.0 GHz THRESHOLD DETECTOR
Rev. 2/16
DTC4001
0.01 TO 4.0 GHz
THRESHOLD DETECTOR
Typical Values @ +25 °C
DTC4001
Wide Frequency Range. . . . . . . . . . . . . . . . . . . . . . . . . 0.01 to 4.0 GHz
Wide Power Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30.0 to -5.0 dBm
Temperature Stability . . . . . . . . . . . . . . . . . . . . . . . . . .
± 0.5 dB
Power Flatness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
± 0.5 dB
Standard Size TO-8 or Surface Mount Package
External Adjustable Threshold Level, Fast Response Time, Low Drift,
Insensitive Threshold Level to Applied Voltage
DTC4001
TO-8 Package for Detectors
SPECIFICATIONS*
Parameter
Frequency (Min.)
Input Power Range (Min.)
VSWR (Max.)
Power Flatness (Max.)
Threshold Temperature Stability
(Max.)
Threshold Hysteresis (Max.)
Pulse Response (Max.)
Logic: Pin > Pth
Output Voltage Hi @ 5mA source
Output Voltage Lo @ 5mA sink
Supply Current (Max.)
Typical
0.01-5.0 GHz
-30 to -5 dBm*
1.5:1†
±0.5 dB^
±0.25 dB^
±0.2 dB
50 µsec^‡
1
4.4 Volts
0.1 Volts
2.5 mA†
Guaranteed
0 to 50 °C -55 to +85 °C
0.01-4.0 GHz
0.01-4.0 GHz
-25 to -5 dBm*
-25 to -5 dBm*
2.0:1†
2.0:1†
±0.75 dB^
±0.75 dB^
±0.5 dB^
±0.5 dB
100 µsec^‡
1
3.5 Volts
0.25 Volts
3.5 mA†
±0.5 dB^
±0.5 dB
100 µsec^‡
1
3.5 Volts
0.25 Volts
3.5 mA†
* Measured in a 50 Ohm system at Vs=+5.0 Vdc. RTH=100 Ohm to 100 KOhm unless otherwise specified.
^ RTH = 1 KOhm. † Pin ≤–15 dBm. ‡ 50% RF to 10 or 90% Video Response time for input change
≥3 dB above Pth.
MAXIMUM RATINGS
DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous RF Input Power . . . . . . . . . . . . . . . . . . . . .
Operating Case Temperature . . . . . . . . . . . . . . . . . . . .
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .
Burn-In Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .
RF Input Power Thermal Resistance (θjc, RF) . . . . . . .
DC Supply Thermal Resistance (θjc, DC) . . . . . . . . . . .
Temperature Rise @ 0 dBm . . . . . . . . . . . . . . . . . . . . .
+7 V
+14.0 dBm
-55 °C to +125 °C
-65 °C to +125 °C
+125 °C
+3.5 °C/mW
+32 °C/W
+4.1 °C
DTS4001
SMTO-8 Package for Detector
APPLICATION NOTES
This unit is DC coupled and employs a RF choke at the input (DC short).
DO NOT bypass the Threshold Control pin. Capacitance greater than 50pF may cause
instabilities. Keep the threshold programming resistor or circuit close to this pin.
Average power detection is obtained at power levels below approximately –13 dBm.
The output of this unit is derived from an op-amp, not a true logic device.
Connect external threshold resistor from Rcntl port to ground.
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com