English
Language : 

AC1219 Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – 10 TO 1200 MHz TO-8 CASCADABLE AMPLIFIERS
Rev. 5/10
AC1218 10 TO 1200 MHz
AC1219 TO-8 CASCADABLE AMPLIFIERS
Typical Values
High Dynamic Range . . . . . . . . . . . . . . . . . . . . .
High Output Power . . . . . . . . . . . . . . . . . . . . . . .
High Third Order I.P. . . . . . . . . . . . . . . . . . . . . . .
High Performance Thin Film
Standard Size TO-8 Package
AC1218
+114 dBm
+19.0 dBm
+32.0 dBm
AC1219
+117 dBm
+22.0 dBm
+33.0 dBm
AC1218/AC1219
TO-8 Package for Amplifiers
SPECIFICATIONS*
Parameter
Frequency (Min.)
Small Signal Gain (Min.)
Gain Flatness (Max.)
Noise Figure (Max.)
SWR (Max.) Input/Output
Power Output (Min.) dBm
@ 1dB comp. AC1218
AC1219
Reverse Isolation
DC Current (Max.) mA
AC1218
AC1219
Typical
5-1250 MHz
11.5 dB
±0.2 dB
4.5 dB
< 1.5:1
12V 15V
+16.0 +19.0
+20.0 +22.0
16.0 dB
Guaranteed*
0 to 50 °C -55 to +85 °C
10-1200 MHz
10.5 dB
10-1200 MHz
10.0 dB
±0.5 dB
±0.7 dB
5.5^ dB
6.5^ dB
1.8:1
2.0:1
12 V 15V
+15.0 +17.5
+17.5 +20.5
12V 15V
+14.5 +17.0
+17.0 +20.0
—
—
45.0 65.0
70.0 88.0
50.0 68.0
75.0 93.0
53.0 71.0
78.0 96.0
* Measured in a 50-ohm system at +15 Vdc unless otherwise specified.
^ 1.0 dB higher above 700 MHz.
INTERMODULATION PERFORMANCE
Typical @ 25 °C; 600 MHz
AC1218
Second Order Harmonic Intercept Point . . . . . +51 dBm
Second Order Two Tone Intercept Point . . . . . . +45 dBm
Third Order Two Tone Intercept Point . . . . . . . . +33 dBm
AC1219
+43 dBm
+37 dBm
+32 dBm
AS1218/AS1219
SMTO-8 Package for Amplifiers
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -62 to +125 °C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+125 °C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+19 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+13 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . . . 100 Milliwatts
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
0.5 Watt
Burn-in Temperature (AC1218) . . . . . . . . . . . . . . . . . . . . . . .
+105 °C
Burn-in Temperature (AC1219) . . . . . . . . . . . . . . . . . . . . . . .
+95 °C
Thermal Resistance1 (θjc; AC1218) . . . . . . . . . . . . . . . . . . . +34 °C/Watt
Thermal Resistance1 (θjc; AC1219) . . . . . . . . . . . . . . . . . . . +32 °C/Watt
Junction Temperature Rise Above Case (Tjc; AC1218) . . .
+34.2 °C
Junction Temperature Rise Above Case (Tjc; AC1219) . . .
+45.1 °C
1 Thermal resistance is based on total power dissipation.
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com