English
Language : 

AC1018 Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – 10 TO 1000 MHz TO-8 CASCADABLE AMPLIFIERS
Rev. 5/10
AC1018
10 TO 1000 MHz
TO-8 CASCADABLE AMPLIFIERS
Typical Values
High Output Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Third Order I.P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low VSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Performance Thin Film
Standard Size TO-8 Package
AC1018
+15.8 dBm
+30.0 dBm
< 1.4:1
AC1018
TO-8 Package for Amplifiers
SPECIFICATIONS*
Parameter
Frequency (Min.)
Small Signal Gain (Min.)
Gain Flatness (Max.)
Noise Figure (Max.)
SWR (Max.)
Input/Output
Power Output (Min.)
@ 1dB comp.
Reverse Isolation
DC Current (Max.)
Typical
5-1100 MHz
14.5 dB
±0.25 dB
3.8 dB
< 1.5:1
+15.8 dBm
18.0 dB
44.0 mA
Guaranteed
0 to 50 °C -55 to +85 °C
10-1000 MHz
10-1000 MHz
14.0 dB
13.5 dB
±0.5 dB
±0.8 dB
5.0 dB
5.5 dB
1.8:1
2.0:1
+15.0 dBm
—
47.0 mA
+14.5 dBm
—
50.0 mA
* Measured in a 50-ohm system at +15 Vdc unless otherwise specified.
INTERMODULATION PERFORMANCE
Typical @ 25 °C
Second Order Harmonic Intercept Point. . . . . . . . . . . . . . .
Second Order Two Tone Intercept Point . . . . . . . . . . . . . . .
Third Order Two Tone Intercept Point . . . . . . . . . . . . . . . . .
AC1018
+49 dBm
+44 dBm
+30 dBm
AS1018
SMTO-8 Package for Amplifiers
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -62 to +125 °C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+125 °C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+18 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+13 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . . . 50 Milliwatts
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
0.5 Watt
Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+100 °C
Thermal Resistance1 (θjc) . . . . . . . . . . . . . . . . . . . . . . . . . . +47 °C/Watt
Junction Temperature Rise Above Case (Tjc) . . . . . . . . . . .
+33.2 °C
1Thermal resistance is based on total power dissipation.
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com