Equation 2 can be used in conjunction with Equation 3
to ensure regulator thermal operation is within limits. For
example:
Given:
VINMAX = 3.0V ±10%
VOUTMIN = 2.7V ±0.5V
ILOAD = 40mA
TAMAX = 55°C
Find: 1. Actual power dissipation
2. Maximum allowable dissipation
Actual power dissipation:
PD ≈ (VINMAX – VOUTMIN)ILOADMAX
= [(3.0 x 1.05) – (2.7 x .995)]40 x 10–3
= 18.5mW
Maximum allowable power dissipation:
PDMAX = (TJMAX – TAMAX)
θJA
= (125 – 55)
220
= 318mW
In this example, the TC1070 dissipates a maximum of
only 60mW; far below the allowable limit of 318mW. In a
similar manner, Equation 2 and Equation 3 can be used to
calculate maximum current and/or input voltage limits.
Layout Considerations
The primary path of heat conduction out of the package
is via the package leads. Therefore, layouts having a ground
plane, wide traces at the pads, and wide power supply bus
lines combine to lower θJA and therefore increase the
maximum allowable power dissipation limit.