English
Language : 

TC1044S Datasheet, PDF (2/8 Pages) TelCom Semiconductor, Inc – CHARGE PUMP DC-TO-DC VOLTAGE CONVERTER
CHARGE PUMP DC-TO-DC
VOLTAGE CONVERTER
TC1044S
ABSOLUTE MAXIMUM RATINGS*
Supply Voltage ......................................................... +13V
LV, Boost and OSC Inputs
Voltage (Note 1) ......................... – 0.3V to (V++ 0.3V)
for V+ < 5.5V
(V+ – 5.5V) to (V++ 0.3V)
for V+ > 5.5V
Current Into LV (Note 1) ...................... 20µA for V+ > 3.5V
Output Short Duration (VSUPPLY ≤ 5.5V) ......... Continuous
Lead Temperature (Soldering, 10 sec) ................. +300°C
Package Power Dissipation (TA ≤ 70°C) (Note 2)
8-Pin CerDIP ..................................................800mW
8-Pin Plastic DIP ............................................. 730mW
8-Pin SOIC .....................................................470mW
Operating Temperature Range
C Suffix .................................................. 0°C to +70°C
I Suffix ............................................... – 25°C to +85°C
E Suffix ............................................. – 40°C to +85°C
M Suffix ........................................... – 55°C to +125°C
Storage Temperature Range ................ – 65°C to +150°C
*Static-sensitive device. Unused devices must be stored in conductive material. Protect devices from static discharge and static fields. Stresses above those
listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only and functional operation of the device
at these or any other conditions above those indicated in the operation sections of the specifications is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS: TA = +25°C, V+ = 5V, COSC = 0, Test Circuit (Figure 1), unless otherwise
indicated.
Symbol Parameter
Test Conditions
Min Typ Max Unit
I+
Supply Current
RL = ∞
0°C < TA < +70°C
– 40°C < TA < +85°C
– 55°C < TA < +125°C
I+
Supply Current
(Boost Pin = V+)
0°C < TA < +70°C
– 40°C < TA < +85°C
– 55°C < TA < +125°C
VH+ 2
Supply Voltage Range, High
Min ≤ TA ≤ Max,
RL = 10 kΩ, LV Open
VL+2
Supply Voltage Range, Low
Min ≤ TA ≤ Max,
RL = 10 kΩ, LV to GND
—
80
160 µA
—
—
180
—
—
180
—
—
200
—
—
300 µA
—
—
350
—
—
400
3
—
12 V
1.5
—
3.5 V
ROUT
Output Source Resistance
IOUT = 20mA
IOUT = 20mA, 0°C ≤ TA ≤ +70°C
IOUT = 20mA, –40°C ≤ TA ≤ +85°C
IOUT = 20mA, –55°C ≤ TA ≤ +125°C
V+ = 2V, IOUT = 3 mA, LV to GND
0°C ≤ TA ≤ +70°C
– 55°C ≤ TA ≤ +125°C
—
60
100 Ω
—
70
120
—
70
120
—
105 150
—
—
250 Ω
—
—
400
FOSC
Oscillator Frequency
Pin 7 open; Pin 1 open or GND
Boost Pin = V+
—
10
— kHz
—
45
—
PEFF
Power Efficiency
RL = 5 kΩ; Boost Pin Open
TMIN < TA < TMAX; Boost Pin Open
Boost Pin = V+
96
98
—%
95
97
—
—
88
—
VOUT EFF
ZOSC
Voltage Conversion Efficiency
Oscillator Impedance
RL = ∞
V+ = 2V
V+ = 5V
99 99.9 — %
—
1
— MΩ
—
100
—
kΩ
NOTES: 1. Connecting any input terminal to voltages greater than V+ or less than GND may cause destructive latch-up. It is recommended that no
inputs from sources operating from external supplies be applied prior to "power up" of the TC1044S.
2. Derate linearly above 50°C by 5.5mW/°C.