English
Language : 

TC1023 Datasheet, PDF (2/6 Pages) TelCom Semiconductor, Inc – PRECISION TEMPERATURE-TO-VOLTAGE CONVERTERS WITH SHUTDOWN MODE
PRELIMINARY INFORMATION
TC1023
TC1024
PRECISION TEMPERATURE-TO-VOLTAGE
CONVERTERS WITH SHUTDOWN MODE
ABSOLUTE MAXIMUM RATINGS *
Supply Voltage ............................................................15V
Input Voltage, Any Terminal .............. – 1.0 to (VCC +0.3V)
Operating Temperature (TC1023) ......... – 20°C to +100°C
Operating Temperature (TC1024) ......... – 20°C to +125°C
Storage Temperature ............................ – 55°C to +150°C
Lead Temperature (Soldering, 10 sec) ................. +300°C
* Static-sensitive device. Unused devices must be stored in conductive
material. Protect devices from static discharge and static fields. Stresses
above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. These are stress ratings only and functional
operation of the device at these or any other conditions above those
indicated in the operational sections of the specifications is not implied.
Exposure to Absolute Maximum Rating Conditions for extended periods
may affect device reliability.
ELECTRICAL CHARACTERISTICS : TA = – 20°C to +125°C, VCC = 5V ±5%, GND = 0V, unless otherwise specified.
Symbol Parameter
Test Conditions
Min
Typ
Max
Unit
VCC
Supply Voltage (TC1023)
(TC1024)
2.2
—
12
V
3.0
—
12
IS
Supply Current
CE = VIL
(Note 1)
—
40
60
µA
ICE
Shutdown Current
CE = VIH
(Note 2)
—
1
5
µA
VIH
CE Input Logic HIGH Level
VIL
CE Input Logic LOW Level
ICE
CE Input Leakage Current
tREC
Recovery Time from Shutdown
CE = VIH or VIL
CE = step from VIH to VIL
(Note 3)
2.0
—
—
—
–1
—
—
400
—
V
0.8
V
+1
µA
—
µsec
VOUT
VOUT Output Voltage (TC1024)
VOUT Output Voltage (TC1023)
TA = – 20°C and +125°C
TA = – 20°C and +100°C
Circuit per Figure 1:
R1 = 240kΩ
VSS = – 12V
(Note 1)
270
—
– 230
—
1780
mV
1030
ISRC
VOUT Output Source Current
Accuracy at Room Temperature
TA = +25°C
(Note 4)
—
—
–2
—
1.0
mA
+2
°C
Accuracy at Minimum Temperature
TC1023: TA = – 20°C
TC1024: TA = – 20°C
(Note 4)
–4
—
+4
°C
Accuracy at Maximum Temperature
TC1023: TA = +100°C
TC1024: TA = +125°C
(Note 4)
–3
—
+3
°C
Nonlinearity
Note 5
– 0.8
—
+0.8
°C
Line Regulation
—
80
—
µV/V
AV
VOUTMAX
Average Slope of Output Voltage
Maximum Output Voltage
TC1023: 2.2V ≤ VCC ≤ 12V
TC1024: 3.0V ≤ VCC ≤ 12V
(Note 1)
—
10
—
mV/°C
—
— VCC – 1.2
V
NOTES: 1. VOUT outputs open circuited.
2. VOUT is 0V through approximately 100kΩ to ground when CE = VIH.
3. Recovery time is the period required for VOUT to rise from 0V (shutdown state) to the voltage corresponding to the measured
temperature driving a 100pF capacitive load.
4. Accuracy = Difference between calculated output voltage (10mV/°C x Device case temperature at specified temperature and power
supply) and measured output voltage expressed in °C.
5. Nonlinearity = deviation of output voltage versus temperature from the best-fit straight line over the device rated temperature range.
TC1023/1024-05 6/12/97