English
Language : 

408-9359 Datasheet, PDF (6/7 Pages) TE Connectivity Ltd – Cumulative Trauma Disorders can result from the prolonged use ofmanually powered hand tools.
AMPMODU MTE Contact
(Not Terminated, Preloaded
in Housing, Typical)
Contact
Housing
(Ref)
Top of Wire
Barrel Slot
Insulation Barrel Supports
Preload Window
0.51 [.020] Min.
A
408- 9359
A
GOOD
Top of Conductor
Top of Wire
Barrel Slot
1.98 [.078]
Max.
Top of Conductor
Shall be Below
Top of Wire Barrel
Slot
1.98 [.078]
Max.
SOLID WIRE
Note: Wire Bundle Dia is Approx. 0.76
[.030] for 22 AWG, 7- Strand Wire.
7- STRAND WIRE
Except No. 22 AWG with
Insulation Dia. 1.14 [.045]
0.10 [.004] Max.
1.98 [.078]
Max.
22 AWG 7- STRAND WIRE
With Insulation Dia
1.14 [.045] Only
1.98 [.078]
Max.
0.51 [.020]
Min.
Wire Pushed
Over
Insulation Pierced
by Insulation Barrel
Supports
One, or Both, Insulation
Barrel Supports Not
Folded Over
Wire Not
Seated
Wire Too
Short
Wire Too
Long
ACCEPTABLE
UNACCEPTABLE
Figure 7
7. REPAIR
Customer--replaceable parts are provided in Figure 8.
A complete inventory should be stocked and
controlled to prevent lost time when replacement of
parts is necessary. Order replacement parts through
your TE Representative, or call 1--800--526--5142, or
send a facsimile of your purchase order to
717--986--7605 or write to:
CUSTOMER SERVICE (038--035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105--3608
For customer repair service, contact a TE
Representative at 1--800--526--5136.
8. REVISION SUMMARY
Revisions to this document include:
S Updated document to corporate requirements
S Changed wire guide in all instances
S Changed part number from 1--21002--8 to
1--21002--7 and description in table in Figure 8
6 of 7
Rev C