3. Place a contact with wire into the proper nest and
close the tool handles until the ratchet reaches the
sixth click, or until the contact support touches the
contact.
4. Slightly loosen the nut that holds the locator
assembly onto the tool frame.
5. Move the contact support as required to eliminate
the bending of the contact.
6. Tighten the nut and close the handles until the
ratchet releases.
7. Remove and inspect the contact.
8. Make another sample crimp. If the contact is
straight, tighten the contact support screw. If the
contact is still being bent during crimping, repeat the
adjustment procedure.
5. CRIMPING PROCEDURE
NOTE
This tool is provided with a crimp adjustment
feature. Initially, the crimp height should be verified
i
as specified in Figure 4. Refer to Section 6, Crimp
Height Inspection, and Section 7, RATCHET
(Crimp Height) Adjustment, to verify crimp height
before using the tool to crimp desired contacts and
wire sizes.
Refer to the table in Figure 1 and select wire of the
specified size and insulation diameter. Strip the wire to
the length indicated in Figure 1, taking care not to nick
or cut wire strands. Select an applicable contact and
identify the appropriate crimp section according to the
wire size markings on the tool. Refer to Figure 3 and
proceed as follows:
1. Hold the tool so that the back (wire side) is facing
you. Squeeze tool handles together and allow them
to open fully.
2. Holding the contact by the mating end, insert the
contact - insulation barrel first - through the front of
the tool and into the appropriate crimp section.
3. Position the contact so that the mating end of the
contact is on the locator side of the tool, and so that
the open "U" of the wire and insulation barrels must
face the top of the tool. Place the contact up into the
nest so that the movable locator drops into the slot
in the contact. Refer to Figure 3. Butt the front end
of the wire barrel against the movable locator.
CAUTION
Make sure that both sides of the insulation barrel
are started evenly into the crimping section. Do not
!
attempt to crimp an improperly positioned contact.
4. Hold the contact in position and squeeze the tool
handles together until ratchet engages sufficiently to
hold the contact in position. Do NOT deform
insulation barrel or wire barrel.
Contact
Support
Adjustment
Screw for
Contact 
Support
Locator
Back of Tool
(Wire Side)
Contact
(Typ)
Strip
Length
Locator
in Wire
Stop Slot
Wire
Figure 3
Wire
Inserted
to Stop
Rev C