English
Language : 

8101 Datasheet, PDF (2/4 Pages) LSI Computer Systems – Gigabit Ethernet Controller
MODEL 8101 ACCELEROMETER
PERFORMANCE SPECIFICATIONS
All values are typical at +24°C, 80Hz and 7Vdc excitation unless otherwise stated. Measurement Specialties reserves the right to update
and change these specifications without notice.
Parameters
DYNAMIC
Range (g)
Sensitivity (mV/g)
Frequency Response (Hz)
Resonant Frequency (Hz)
Non-Linearity (%FSO)
Transverse Sensitivity (%)
Shock Limit (g)
Residual Noise (g RMS)
Spectral Noise, 10Hz (µg√Hz)
Spectral Noise, 100Hz (µg√Hz)
Spectral Noise, 1kHz (µg√Hz)
±40
50.0
2-6000
>30000
±2
<8
2000
0.008
160
40
16
±160
12.5
2-6000
>30000
±2
<8
2000
0.008
160
40
16
Notes
±30%
±1dB
2Hz to 10kHz
ELECTRICAL
Bias Voltage (Vdc)
Full Scale Output Voltage (V)
Total Supply Current (µA)
Excitation Voltage (Vdc)
Output Impedance (Ω)
Insulation Resistance (MΩ)
Shielding
Ground Isolation
Warm-up Time (msec)
2.5
±2
800
7 to 36
<100
>100
100%
Isolated from Mounting Surface
30
@100Vdc
ENVIRONMENTAL
Temperature Response (%)
Operating Temperature (°C)
Storage Temperature (°C)
Humidity (Active Element & Electronics)
Humidity (Case)
-20/+20 from -40°C to +85°C
-40 to +85
-40 to +85
Hermetically Sealed
Epoxy Sealed, IP65
PHYSICAL
Case Material
Cable
Weight (grams)
Mounting
Anodized Aluminum
4x #32 AWG Conductors PFA Insulated, Braided Shield, PU Jacket
3.6
Epoxy or Double-sided tape
Cable not included
Calibration supplied: CS-SENS-0100 NIST Traceable Amplitude Calibration at 80Hz
Optional accessories: CS-FREQ-0100 NIST Traceable Amplitude Calibration from 20Hz to ±1dB Frequency Response Limit
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this
information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right
to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability
of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and
specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications.
All operating parameters must be validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license
under its patent rights nor the rights of others.
SENSOR SOLUTIONS /// EPIH_en_RevB
9/2015
Page 2