English
Language : 

408-1254 Datasheet, PDF (2/6 Pages) TE Connectivity Ltd – Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
408-1254
Terminal
“B”
Flag Terminal
“B”
Standard Butt Splice
“B”
Parallel Splice
“B”
Butt Splice with Sight Hole
“B” Equals Wire Barrel
TOOL
NUMBER
69339D
69354-1DD
69355DDD
WIRE
SIZE
CIRCULAR
MILL AREA
RANGE
8
8 13,100-20,800
8
TERMINAL
Min.
Max.
8.33
[.328]
9.12
[.359]
---
---
8.33
[.328]
9.12
[.359]
WIRE STRIP LENGTH (mm [in.])
FLAG TERMINAL
BUTT SPLICE
Min.
Max.
Min.
Max.
---
---
10.31
[.406]
11.13
[.438]
9.52
[.375]
11.13
[.438]
---
---
---
---
10.31
[.406]
11.13
[.438]
PARALLEL SPLICE
Min.
Max.
10.31
[.406]
11.13
[.438]
---
---
10.31
[.406]
11.13
[.438]
DStranded wire only. DDFlag terminals only. DDDAlso used for STRATO-THERM Heat Resistant Terminals.
Figure 2
"A" Terminal
Bottom of Terminal
Tongue Faces Top
of Tool
"B" Flag Terminal
Crimp Flag Terminals
Only in Tools
Designated
for Flag
Center Wire
Barrel in Dies
End of Wire is Flush
with or Extends Beyond
End of Wire Barrel
Tongue Portion
of Wire Barrel is
Against lndenter
Figure 3
"A" Standard Butt Splice
"B" Butt Splice with Sight Hole
"C" Parallel Splice
Internal Wire Stop
Faces Top of Tool
End of Wire Butts
Against Wire Stop
Internal Wire Stop
Faces Top of Tool
End of Wire Butts
Against Wire Stop
Ends of Wires
are Flush with
or Extend
Beyond End of
Wire Barrel
Center
Wire
Barrel
in Dies
When Brazed Seam
on Splice is Visible,
Position Seam
Toward Indenter
Sight Hole
Faces Indenter
Center
Splice
in Dies
When Brazed
Seam on Splice
is Visible,
Position Seam
Toward
Indenter
Figure 4
Rev D
2 of 6