DYNAMIC
Range (g)
Sensitivity (mV/g)
Frequency Response (Hz)
Non-Linearity (%FSO)
Transverse Sensitivity (%)
Shock Limit (g)
Residual Noise (µV RMS)
Residual Noise (µg/√Hz RMS)
Self Test Output Change (mV)
±2
1000
0-200
±1
<3
2000
600
50
X = +210 ±90
Y = -210 ±90
Z = -340 ±190
±6
333
0-200
±1
<3
2000
240
42
X = +70 ±30
Y = -70 ±30
Z = -110 ±65
Notes
±10%
±5%
Passband
Ground ST Lead
ELECTRICAL
Zero Acceleration Output (V)
Excitation Voltage (Vdc)
Excitation Current (mA)
Full Scale Output Voltage (Vdc)
Ground Isolation
2.5 ±0.1
5 to 30
4
±2
Isolated from Mounting Surface
ENVIRONMENTAL
Thermal Zero Shift (%FSO)
Thermal Sensitivity Shift (%)
Operating Temperature (°C)
Humidity
±4
±5
-40 to 85
Epoxy Sealed, IP65
-40° to +85°C
-40° to +85°C
PHYSICAL
Housing Material
Weight (grams)
Mounting
Mounting Torque
Nylon 6-6, 30% GF, Brass Inserts at Mounting Holes
50
2x ¼ or M6 Screws
18 lb-in (2.0 N-m)
Optional accessories:
121
3-Channel Precision Low Noise DC Amplifier
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this
information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right
to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability
of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and
specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications.
All operating parameters must be validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license
under its patent rights nor the rights of others.
SENSOR SOLUTIONS /// Model 4020 & 4030 Rev B
9/2015
Page 2