English
Language : 

T9S Datasheet, PDF (1/2 Pages) TE Connectivity Ltd – General Purpose Relays Power Relays
General Purpose Relays
Power Relays
Power PCB Relay T9S Solar
n
1 pole 35A, 1 form A (NO) contact
n
Contact gap >1.5mm (standard), >1.8mm (suffix S)
n
350mW hold power
n
Ambient temperature up to 85°C at 35A
n
The appliance is able to meet VDE V 0126-1-1
n
Product in accordance to IEC 60335-1
n
EN61095: AC7a at 85°C
Potter & Brumfield
Typical applications
Photovoltaic inverter
U
f0156_bc_inv
Approvals
VDE 40030974, UL E58304
Technical data of approved types on request
Contact Data
Contact arrangement
1 form A (NO)
Contact gap >1.5mm (standard), >1.8mm (suffix S)
Rated voltage
250VAC (1.8mm gap), 277VAC (1.5mm gap)
Rated current
35A1)
Breaking capacity max.
8750 VA
Contact material
AgNi
Initial contact resistance 75mΩ max. at 1A 6VDC
Frequency of operation, with/without load
6/300min-1
Operate/release time max., incl bounce time 18/15ms
Contact ratings2)
Type
Contact
IEC 61810
T9SV1K15-12 A (NO)
T9SV1K15-12S A (NO)
UL 508
T9SV1K15-12 A (NO)
T9SV1K15-12S A (NO)
Load
35A, 250VAC, cosφ=1, 85°C
35A, 250VAC, cosφ=1, 85°C
35A, 277VAC, resistive, 85°C
35A, 250VAC, resistive, 85°C
Cycles
30x103
20x103
30x103
20x103
Mechanical endurance, DC coil
1x106 operations
1) The relay connections and wiring have to be designed with an adequate cross sections
to ensure the current flow and heat dissipation.
2) Contact ratings with relay properly verted.
Coil Data
Rated coil voltage
Coil insulation system according UL
12VDC
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%
W
12
122)
9.6
0.8
64+10%
2.25 /
min. 0.35
hold
2) After the energization time of 100 ms with 12 VDC the coil requires a reduction of the coil
voltage to 4.7...6.0 VDC.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
Material group of insulation parts
Tracking index of relay base
2500Vrms
4000Vrms
3/4mm
III
PTI 325
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-40 to +85°C1)
Category of environmental protection
IEC 61810
RTII - flux proof
Vibration resistance (functional)
10g
Shock resistance (functional)
10g
Shock resistance (destructive)
100g
Terminal type
PCB-THT
Mounting
see note1)
Mounting distance
≥10mm
Weight
appr. 30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging unit
box/500 pcs.
1) The relay connections and wiring have to be designed with an adequate cross sections
to ensure the current flow and heat dissipation.
09-2016, Rev. 0916
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions