English
Language : 

SRL7 Datasheet, PDF (1/2 Pages) TE Connectivity Ltd – Reinforced insulation between contact circuits
General Purpose Relays
Force Guided Relays
Force Guided Relay SRL7
n Low profile relay with force guided contacts
according to EN 50205
n 5 form A (NO) + 2 form B (NC) contacts
n Reinforced insulation between contact circuits
SCHRACK
Typical applications
Emergency stop or two hand guard safety relays, expansion I/O modules,
safety control circuits
Approvals
VDE Cert. No. 40036240, UL E214025, TÜV 968/EL908
Technical data of approved types on request
Contact Data
Contact arrangement 5 form A + 2 form B contacts,
(5 NO + 2 NC)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
6A
Sum of the squared currents
72A2
Contact material
Ag alloy
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V/10mA
Initial contact resistance ≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/30min-1
Mechanical endurance
10x106 operations
Contact ratings
Contact
Load Cycles
UL508
NO/NC 6A, 250VAC, general purpose, 85°C
6.000
IEC61810
NO/NC 6A, 250VAC, cosphi=1, 50% DF, 85°C 6.000
SRL7
ZT
Coil Data
Coil voltage range
Operative range, IEC 61810
Max. coil power
5 to 110VDC
2
700mW
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%
mW
005
5
3,8
0,5
36
694
006
6
4,5
0,6
51
706
009
9
6,8
0,9
116
698
012
12
9
1,2
206
699
015
15
11,3
1,5
319
705
018
18
13,5
1,8
463
700
021
21
16
2,1
630
700
024
24
18
2,4
820
702
036
36
27
3,6
1850
701
048
48
36
4,8
3290
700
060
60
45
6
5140
700
110
110
83
11
17280
700
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Insulation Data
group A
group B
Initial dielectric strength
between open contacts
1000Vrms
1000Vrms
between contact and coil
4000Vrms
2500Vrms
between adjacent contacts
4000Vrms
2500Vrms
between group A and group B
4000Vrms
Clearance/creepage
between open contacts
microdisconnection
between contact and coil
≥5.5/5.5mm
≥3/4mm
between adjacent contacts
≥5.5/5.5mm
≥3/4mm
between group A and group B
≥5.5/5.5mm
Insulation to EN 50178, type of insulation
between contact and coil
reinforced
basic
between adjacent contacts
reinforced
basic
between group A and group B
reinforced
Other Data
Ambient temperature
Category of environmental Protection
IEC 61 810
Packaging/unit
-40 to 85°C
RTII
20 pcs. tray
100 pcs. box
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions