English
Language : 

SR6-D Datasheet, PDF (1/2 Pages) TE Connectivity Ltd – High insulation distances between electrical circuits
General Purpose
Force Guided Relays
Force Guided Relay SR6 D/M
n 4 pole relay with force guided contacts according to EN 50205
n High insulation distances between electrical circuits
SCHRACK
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays.
F0206-ED
ZT
Approvals
VDE Cert. No. 128935, UL E214025, TUV 968/EL 350
Technical data of approved types on request.
Contact Data
Contact arrangement
3 form A + 1 form B contacts
3 NO + 1 NC,
2 form A + 2 form B contacts
2 NO + 2 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V, 10mA
Initial contact resistance ≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings, IEC60947-5-1,
on 1 form A (NO) contact
AC15-5A
DC13-6A
Mechanical endurance
10x106 operations
Coil Data (continued)
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%1)
mW
024
24
18
2.4
480
1200
036
36
27
3.6
1080
1200
040
40
30
4.0
1333
1200
048
48
36
4.8
1920
1200
060
60
45
6
30001)
1200
110
110
83
11
100801)
1200
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.8
006
6
4.5
009
9
6.8
012
12
9
018
18
13.5
021
21
16
Release
voltage
VDC
0.5
0.6
0.9
1.2
1.8
2.1
Coil
resistance
Ω±10%1)
21
30
68
120
270
368
Rated coil
power
mW
1190
1200
1191
1200
1200
1198
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
in longitudinal direction
Clearance/creepage
between open contacts
between contact and coil
between adjacent contacts
in longitudinal direction
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
1500Vrms
4000Vrms
3000Vrms
4000Vrms
microdisconnection
≥5.5/5.5mm
≥5.5/5.5mm
≥15/15mm
reinforced
reinforced
01-2015, Rev. 0115
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.