PD5 Datasheet, PDF (1/1 Pages) TE Connectivity Ltd – KILOVAC 28 - 1800 Vdc High Voltage Relays
KILOVAC 28 - 1800 Vdc High Voltage Relays
PD5 Make & Break Load Switching
Product Facts
n Vacuum dielectric for power
switching
n Excellent for control
applications
n PCB and panel mountings
n Rugged design for the most
demanding applications,
including seismic shock
n Small size and weight
n Low power consumption
n No heat sinks required
n Vacuum-sealed; can operate
in explosive and harsh
environments
n 2000 V isolation across
open contacts
Product Specifications
Contact Arrangement —
PD5A — SPST-NO
PD5B — SPST-NC
Contact Form —
PD5A — A**
PD5B — B**
Rated Resistive Load @ 320 Vdc —
5A
Continuous Current Carry, Max.
@ 85°C — 15 A
Overload @ 320 Vdc,
(Make/Break) — 20 A
Life, (Mechanical/Rated Load) —
500k cycles/50k cycles
Contact Resistance, Max.,
End of Life — 0.010 ohm
Dielectric at Sea Level —
Power Terminals to Coil and
All Other Points — 1,800 Vrms
Shock, 11ms, 1/2 Sine (Peak) —
25 g
Vibration, Sinusoidal
(55-2000 Hz, Peak) — 5 g
Operating Ambient Temperature
Range — -40°C to +85°C
Operate Time, Max., Including
Bounce @ 25°C — 10 ms
Release Time, Max., Including
Bounce @ 25°C — 10 ms
Insulation Resistance @ 500 Vdc,
Min. —
Initial/End of Life — 100 mohm/50 mohm
Weight, Nominal —
57 g (.125 lb)
Contact Ratings*
*Based on extrapolated data. Since each application is unique, user is encour-
aged to verify rating in actual application. The load terminals should always be
connected as follows: Common Contact (A2) positive; Other Contact negative.
Coil Data
Nominal Volts DC
Max. Coil Voltage
Pickup, Max. @ 85°C
Hold, Min. @ 85°C
Dropout, Min. @ -40°C
Coil Resistance (±10%)
12 Vdc
14 Vdc
8 Vdc
3.3 Vdc
.5 Vdc
70 Ω
Ratings listed are for 25°C, sea level conditions
24 Vdc
28 Vdc
16 Vdc
10 Vdc
1 Vdc
290 Ω
125 Vdc
130 Vdc
80 Vdc
33 Vdc
5 Vdc
4700 Ω
Ordering Information
Sample Part Number ᮣ
PD5 A 2 3 5
Series:
Contact Form:
A = SPST-NO
B = SPST-NC
C = SPDT (PCB Only)
7
Note:
**Contact TE for availability of other
contact forms
Coil Voltage:
2 = 12 Vdc, PCB Version 3 = 24 Vdc, PCB Version
5 = 125 Vdc, PCB Version
A = 12 Vdc, Panel Mount Version
B = 24 Vdc, Panel Mount Version
C = 125 Vdc, Panel Mount Version
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Power Terminals:
3 = PCB Solder Connection
5 = Stud Terminal, Panel Mount
Mounting:
5 = PCB Mount
7 = Panel Mount
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters USA: +1 800 522 6752
unless otherwise specified. Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com