English
Language : 

F4-A Datasheet, PDF (1/3 Pages) TE Connectivity Ltd – Automotive Relays Plug-in Mini ISO Relays
Automotive Relays
Plug-in Mini ISO Relays
Shrouded Power Relay F4 A
n Pin assignment similar to ISO 7588 part 1
n Plug-in terminals
n Customized versions on request
– Integrated components (e.g. resistor, diode)
– Customized marking/color
– Special cover with bracket
Typical applications
Cross carline up to 40A for example: ABS control, blower fans, cooling
fan, energy management, engine control, fuel pump, heated front screen,
lamps: front, rear, fog light, main switch/supply relay, wiper control.
Contact Data
Contact arrangement
1 form A, 1 NO 1 form C, 1 CO
Rated voltage
12VDC
12VDC
Limiting continuous current
NO
NO/NC
23°C, form A/form B
60A
60/45A
85°C, form A/form B
40A
40/30A
125°C, form A/form B
17A
17/12A
Limiting making current1)
form A/form B
120A
120/45A
Limiting breaking current,
form A/form B
60A
60/40A
Limiting short-time current
overload current, ISO 8820-32)
1.35 x 40A, 1800s
2.00 x 40A, 5s
3.50 x 40A, 0.5s
6.00 x 40A, 0.1s
Jump start test, ISO 16750-1
24VDC for 5min,
conducting nominal current at 23°C
Contact material
Silver based
Min. recommended contact load3)
1A at 5VDC
Initial voltage drop at 10A,
form A (NO), typ./max.
15/200mV
15/200mV
form B (NC), typ./max.
-
25/200mV
Frequency of operation at nominal load
6 ops./min (0.1Hz)
Operate/release time typ.
7.4/4ms4)
Electrical endurance
>1x105ops
>1x105ops
resistive load, NO contact
40A, 14 VDC 40A, 14 VDC
F136_fcw3c_bw
Contact Data (continued)
Mechanical endurance
>1x106ops
1) The values apply to a resistive or inductive load with suitable spark suppression and
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current
duration of maximum 3s for a make/break ratio of 1:10.
2) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding.
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance5) power5)
VDC
VDC
VDC
Ω±10%
W
001
12
7.2
1.6
114
1.3
5) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Max. DC load breaking capacity
Coil operating range
Coil 114,0 Ohm, 680 Ohm parallel resistor
30
Umax
25
136_OVR1
20
15
Uop (E=13,5V)
10
5
Uop (E=0V)
Load limit curve 1: arc extinguishes during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
10-2015, Rev. 1015
www.te.com
© 2015 TE Connectivity.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
0
-40
-20
0
20
40
60
80
Ambient temperature in °C
100
120
Does not take into account the temperature rise due to the contact current
E = pre-energization.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions