English
Language : 

EEJ Datasheet, PDF (1/7 Pages) TE Connectivity Ltd – Cost-effective Medium Performance Power Inlet Filter
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Cost-effective Medium Performance Power Inlet Filter
EEJ Series
Including the EJH/EJHS, EJM/EJMS and EJS Models
UL Recognized
CSA Certified
VDE Approved*
20EJH1
3EEJ1
20EEJ8
EEJ Series
• Compact EMI filter with IEC 60320-1 C14 Inlet
• Enhanced two element circuit provides medium
attenuation to 30MHz
• Compact and cost-effective design
• Supersedes most ED Series versions
• Includes 20A version with standard IEC 60320-1
C20 inlet
• Several termination styles
• Flanged mounting
EJS Models
• Same performance as the EEJ Series
• Snap-in mounting
• Several termination styles
• Includes 20A version with standard IEC 60320-1
C20 inlet
Specifications
Maximum leakage current each Line to Ground:
EEJ/EJS EJH
EJM
@ 120 VAC 60 Hz:
.22 mA 2 A .01 mA
@250 VAC 50 Hz:
.38 mA 5 A .017 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max.):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
1 to 20A*
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the
maximum
operating
current (Io)
follows: Io
is calculated as
= Ir (85-Ta)/45
EJH & EJHS Models
• Minimal leakage current suitable for patient-
contact medical applications
• Flanged mounting the same as the EEJ Series
• Also available in snap-in versions (EJHS)
• Two element circuit provides modest EMI
attenuation above 1MHz
• Capacitive input (refer to the H Series for
capacitive output)
• EJHS models feature snap-in mounting
EJM & EJMS Models
• Low leakage current, suitable for most medical
applications
• Improved EMI attenuation up to 200MHz
• Mechanically the same as the EEJ Series with
flange or snap-in mounting
• EJMS models feature snap-in mounting
Electrical Schematic
LINE
LOAD
1
1
Note 1: Not present in EJH versions
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
20A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 16A, 250VAC
3
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
153
For email, phone or live chat, please go to
te.com/help
corcom.com