English
Language : 

C-MEDIUM Datasheet, PDF (1/1 Pages) TE Connectivity Ltd – THIS DRAWING IS A CONTROLLED DOCUMENT.
4
THIS DRAWING IS UNPUBLISHED.
C COPYRIGHT
3
RELEASED FOR PUBLICATION
ALL RIGHTS RESERVED.
MINIMUM INSERTION LOSS, 50
LINE TO GROUND (COMMON MODE)
D
CURRENT
FREQUENCY, MHz
RATING .15 .5 1 3 10 30
3 AMP 50 60 60 49 40 30
6 AMP 34 58 58 47 37 30
10 AMP 6 35 45 45 38 30
LINE AND LOAD IMPEDANCES
LINE TO LINE (DIFFERENTIAL MODE)
CURRENT
FREQUENCY, MHz
RATING .15 .5 1 3 10 30
3 AMP 25 60 60 53 45 40
6 AMP 9 50 62 54 46 40
10 AMP 10 20 59 54 48 40
2.73
C
1.22
2.45
.21
1.95
.23
2
LOC
DIST
P
LTR
REVISIONS
DESCRIPTION
1
DATE
DWN
APVD
PANEL CUT-OUT
D
R .06
.135
1.575
PE VERSIONS
1.120
+.008
-.000
FOR PS VERSIONS THE SHORT EDGES MUST
HAVE R.02 ON INSERTION SIDE.
* FOR PANEL THICKNESS 0.031-0.079 USE 2.201
FOR PANEL THICKNESS 0.083-0.114 USE 2.213.
2.201
+.008
-.000
*
2.496
PM VERSIONS
2.71
2.43
.13
.23
.23
ALLOW .15
FOR SWITCHED
VERSIONS
2.71
2.43
.340
.206
.55
C
.28
2.29
.13
2.88
.23
2.12
PS
SNAP-IN
MOUNTING
B
2.75
PS
PE
SHOWN
WITHOUT SWITCH
PART NUMBER SYSTEM
PS0S0SM6E
MOUNTING STYLE
S = SEE ABOVE
E = SEE ABOVE
M = SEE ABOVE
CURRENT
3 = 3 AMP
6 = 6 AMP
X = 10 AMP
SWITCH OPTIONS
0 = NONE
S = DOUBLE POLE,
SINGLE THROW
PS0S0SM6E EXAMPLE:
SNAP-IN MOUNTING
WITH SWITCH
SINGLE FUSING
A
6 AMP
FUSE LOCATIONS
0'S ARE ZEROS.
D = DUAL FUSING
S = SINGLE FUSING
INCLUDES CONVERSION CLIP
1470-19 (3/11)
2.73
PE
PM
SHOWN WITH
SWITCH
HIPOT RATING (ONE MINUTE)
LINE TO GROUND:
1500 VAC
LINE TO LINE:
1450 VDC
OPERATING FREQUENCY: 50/60 Hz
RATED VOLTAGE:
120/250 VAC
FUSING: ACCEPTS 3AG
1/4" X 1-1/4"
OR METRIC
5 mm X 20 mm
OPERATING AMBIENT TEMP: -10°C TO 40°C
STORAGE TEMPERATURE: -40°C TO 85°C
THIS DRAWING IS A CONTROLLED DOCUMENT.
DWN
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
CHK
APVD
MATERIAL
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
PRODUCT SPEC
APPLICATION SPEC
WEIGHT
2.73
1.14
PM
PS
MAX LEAKAGE CURRENT .25mA
B
@ 120V 60Hz
PER LINE TO GROUND: .50mA
@ 250V 60Hz
HUMIDITY:
21 DAYS, 40°C
@ 95%RH
CURRENT OVERLOAD: 6X RATED FOR 8 SEC
SWITCH: 10K CYCLES
@ 51 AMP INRUSH
TERMINALS: 0.187" X .032 FASTON TABS
SAFETY AGENCIES: UL RECOGNIZED,
CSA CERTIFIED,
VDE APPROVED.
TE Connectivity
NAME
SIZE
CAGE CODE
A3
DRAWING NO
SCALE
A
RESTRICTED TO
SHEET
OF
REV