English
Language : 

408-6795 Datasheet, PDF (1/4 Pages) TE Connectivity Ltd – Reason for revision is given in Section 8, REVISION SUMMARY.
MTA Terminating Head 58082-1
Instruction Sheet
408-6795
01 SEP 11 Rev A
Index Pawl
Wire Inserter
Feed Slide
Head
Adjuster
WIRE SIZE
(AWG)
18
20
22
24
26
POSTED CONNECTORS (MTA-156)
COLOR
CODE
CLOSED
END
FEED
THROUGH
Orange
641435
641522
Yellow
641436
641523
Red
641437
641524
Natural
641438
641525
Blue
641439
641526
Figure 1
1. INTRODUCTION
This instruction sheet covers the operation and
maintenance of TE Connectivity MTA Terminating
Head 58082-1 for use in Pistol Grip Manual Handle
Assembly 58074-1, or Pistol Grip Pneumatic Handle
Assembly 58075-1. Read these instructions
thoroughly before using the heads. Refer to the
instructions packaged with the pistol grip handle
assembly for head installation and removal.
NOTE
i
Dimensions in this instruction sheet are in
millimeters [with inches in brackets]. Figures and
illustrations are for reference only and are not
drawn to scale.
Reason for revision is given in Section 8, REVISION
SUMMARY.
2. DESCRIPTION
This head is designed to terminate wires in MTA
(Mass Termination Assembly) posted connectors with
contacts on 3.96 mm [.156] centers (MTA-156). See
table in Figure 1.
The MTA system uses the Insulation Displacement
Technique which is a method of inserting unstripped
wire into a slotted contact beam to form a reliable
electrical connection between the conductor and
contact.
After the head is inserted into the pistol grip handle
assembly, it serves as a guide and support for the
connector during termination. Features of the head
(see Figure 1) and their functions are as follows:
Wire Inserter - forces wire into the two slotted beams
of the contact. (Note that it provides support for the
contact beams when applying insertion force on the
wire.)
Adjuster - is a piston for - and regulates travel of - the
wire inserter.
Feed Slide - automatically positions the connector
after each termination.
Index Pawl - aligns connector for insertion, and retains
it during termination
3. SETUP ADJUSTMENTS AND TEST
The adjuster (insertion rod) of the wire inserter is
present for wire sizes 18 through 26 AWG. If the wire
is being inserted too deep or not deep enough inside
the contact, it may be necessary to adjust the depth of
the wire inserter; or, if the pneumatic handle assembly
is being used, it may be necessary to adjust either the
air pressure or the depth of the wire inserter.
3.1. For Pistol Grip Manual Handle Assembly
1. Determine the wire size, and select the
appropriate connector. (Connectors are color-coded
according to the wire sizes they accommodate.)
2. Using a small knife, cut off the wire retainers
(strain relief). This will provide a clear view for
inspecting the connector for a properly terminated
wire in the contact. See Figure 2.
CAUTION
Wire retainers are removed to provide a connector
for testing only. Do NOT use such connectors for
!
production applications.
3. Place connector in tool and make a test
termination using procedure described in Section 4,
TERMINATING PROCEDURE, Steps 1 through 6.
4. Push connector out of right side of head.
5. Inspect termination in accordance with Section 5,
INSPECTION, Steps 1 through 6.
If you determine that the wire insertion depth is
incorrect, proceed to Paragraph 3.3, Wire Insertion
Depth Adjustment.
©2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
1 of 4
LOC B