B25655J4307K001 Datasheet, PDF (7/7 Pages) EPCOS – PCC series for Mild HEV HybridPACK™1
Cautions and Warnings
PRELIMINARY
Specifications and characteristics
Capacitance tolerance
tan δ0
VR
Vs
K ±10% / J ±5%
2 · 10-4
450 / 500 / 900 V DC
600 / 700 / 1300 V DC
Test data
Voltage between terminals VTT
Voltage between terminals and case VTC
Rins C
Life expectancy
FQ
Values after Test Ca, IEC 68-2 (21 days, 40 °C, 93% rel. humidity)
|C/C|
tan
Rins C
Tested based on AEC Q-200 rev. D
675 / 750 / 1350 V DC, 10 s
3000 V DC, 10 s
≥10000 s
Up to 15 000 hours @ THS 1)
300 fit
≤5%
≤5 · 10-4
≤3000 s
Climatic category
Tstg
Tmin
Tmax
THS (maximum hot spot temperature)
Max. permissible humidity
40/105/21
-45 ... +110 °C
-40 °C
+105 °C
+105 °C
95%
Construction and general data
Resin filling
Case
Terminals
Creepage and clearance distance
Cooling
Degree of protection
RoHS compliant
Polyurethane resin
Plastic (Polycarbonate)
Flat copper (tinned)
Figure 1: 9 mm
Figure 2: 8 mm
to be confirmed
Indoor mounting (IP54)
1) To be confirmed; depending on the application
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets, data books, other
publications and the website of EPCOS, or in order-related documents such as shipping notes, order confirmations and
product labels. The varying representations of the ordering codes are due to different processes employed and do not
affect the specifications of the respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
HybridPack is a trademark of Infineon Technologies AG
Important information Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our
knowledge of typical requirements that are often placed on our products. We expressly point out that these statements cannot be regarded as binding statements about the suitability of
our products for a particular customer application. It is incumbent on the customer to check and decide whether a product is suitable for use in a particular application. This publication
is only a brief product survey which may be changed from time to time. Our products are described in detail in our data sheets. The Important notes (www.epcos.com/ImportantNotes)
and the product-specific Cautions and warnings must be observed. All relevant information is available through our sales offices.
© EPCOS AG  A TDK Group Company