EMC Components
ACH seriesɹACH32C Type
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SPECIFICATION TABLE
Rated voltage
(V)max.
50
50
50
50
50
50
50
50
50
50
Rated current
(A)max.
6
6
6
6
6
6
6
6
6
6
Insulation resistance DC resistance
(M: )min.
(m: )max.
100
2
100
2
100
2
100
2
100
2
100
2
100
2
100
2
100
2
100
2
Guaranteed
insertion loss
(dB)
–15
–15
–15
–20
–20
–25
–25
–25
–25
–25
˓ Measurement equipment
Measurement item
Product No.
Insertion loss
E5071B
DC resistance
4338A
Insulation resistance
4339A
ˎ Equivalent measurement equipment may be used.
Manufacturer
Agilent Technologies
Agilent Technologies
Agilent Technologies
Guaranteed frequency
bandwidth
Part No.
(MHz)
2000 to 6000
ACH32C-100-T001
1300 to 2500
ACH32C-220-T001
650 to 2500
ACH32C-470-T001
450 to 1300
ACH32C-101-T001
200 to 800
ACH32C-331-T001
100 to 350
ACH32C-102-T001
55 to 300
ACH32C-222-T001
30 to 200
ACH32C-103-T001
10 to 300
ACH32C-333-T001
3.5 to 200
ACH32C-104-T001
INSERTION LOSS VS. FREQUENCY CHARACTERISTICS
0
10
20
30
100
220
470
40
101
331
50
102
104
103 222
60
333
70
80
1
10
˓ Measurement equipment
Product No.
Manufacturer
E5071B
Agilent Technologies
ˎ Equivalent measurement equipment may be used.
100
Frequency (MHz)
1000
10000
• All specifications are subject to change without notice.
001-01 / 20130722 / e9611_ach.fm