English
Language : 

B81192 Datasheet, PDF (5/16 Pages) EPCOS – Film Capacitors EMI Suppression Capacitors (MKP)
B81192
X3 / 250 V AC
Technical data
Max. operating temperature Top,max
Dissipation factor tan δ (in 10-3)
at 20 °C (upper limit values)
+85 °C
at
1 kHz
CR ≤ 0.33 µF CR > 0.33 µF
1.0
1.0
100 kHz
5.0
10
Insulation resistance Rins
or time constant τ = CR  Rins
at 20 °C, rel. humidity ≤ 65%
(minimum as-delivered values)
CR ≤ 0.33 µF
15 GΩ
CR > 0.33 µF
5 GΩ
DC test voltage
1850 V, 2 s
Passive flammability category
B
to IEC 40 (CO) 752
Maximum continuous AC voltage (VAC) 250 V (50/60 Hz)
Rated AC voltage (IEC 60384-14)
250 V (50/60 Hz)
Maximum continuous DC voltage (VDC) 560 V
Operating AC voltage Vop at high
TA ≤
Vop = VAC
(continuously)
temperature
TA ≤
Vop = 1.25  VAC (1000 h)
Damp heat test
56 days / 40 °C / 93% relative humidity
Limit values after damp heat test
Capacitance change ∆C/C
≤ 3%
Dissipation factor change ∆ tan δ ≤ 0.5  10-3 (at 1 kHz)
Insulation resistance Rins
≤ 1.0  10-3 (at 10 kHz)
or time constant τ = CR  Rins
≥ 50% of minimum
as-delivered values
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k0 values
Lead spacing
dV/dt in V/µs
k0 in V2/µs
10 mm
60
42 000
15 mm
50
35 000
22.5 mm
30
21 000
27.5 mm
20
14 000
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 16