English
Language : 

ZJYS Datasheet, PDF (4/5 Pages) TDK Electronics – Common Mode Filters For General Signal Line
(3/4)
ELECTRICAL CHARACTERISTICS
Part No.
Rated voltage Edc(V)
Rated current (A)
Test voltage Edc(V)
[Between terminals for 5s]
Insulation resistance (MΩ )
[Between terminals at DC.50V for 1min]
DC resistance (Ω ) [Each line]
Operating temperature range (°C)
Impedance (Ω ) [+5 to +35°C]
ZJYS51R5-2P(T)-01,
4P(T)-01
50
2
125
ZJYS51R5-2PB(T)-01∗1
50
2
125
100 min.
0.12 max.
–25 to +85
200 min.[20 to 300MHz]
100 min.
0.12 max.
–25 to +85
300 min.[6 to 20MHz]
∗1 The improvement type on low area characteristics.
∗2 Separate winding type (for communications).
• The “T” designation at the end of the product code indicates tape mounting.
ZJYS51R5-2PL(T)-01∗2
50
2
250
100 min.
0.10 max.
–25 to +85
100 min.[20 to 100MHz]
ZJYS51R5-M4PA(T)-01
50
0.5
125
100 min.
0.25 max.
–25 to +85
200 min.[20 to 300MHz]
TYPICAL ELECTRICAL CHARACTERISTICS
IMPEDANCE vs. FREQUENCY CHARACTERISTICS (for 1 element)
ZJYS51R5-2P-01, 4P(T)-01
ZJYS51R5-2PB-01
10000
10000
ZJYS51R5-2PL-01
10000
1000
Common mode
100
Differential mode
10
1000
Common mode
100
Differential mode
10
1000
100
10
Common mode
Differential mode
11
3
10 30 100 300 1000
Frequency(MHz)
11
3
10 30 100 300 1000
Frequency(MHz)
11
3
10 30 100 300 1000
Frequency(MHz)
ZJYS51R5-M4PA-01
10000
1000
Common mode
100
10
Differential
mode
11
3
10 30 100 300 1000
Frequency(MHz)
MEASURING CIRCUIT
Vector
impedance
meter
Vector impedance meter(YHP 4191A equivalent)
Measuring at each Common mode choke coil
• All specifications are subject to change without notice.
001-03 / 20110926 / e971_zjys