Z10-20-U Datasheet, PDF (2/2 Pages) TDK Electronics – 200 to 800W Programmable Power Supplies | |||
|
◁ |
Z+ Series
Speciï¬cations (See website for detailed speciï¬cations)
Model
Load Regulation
CV
Line Regulation
CV
Recovery Time
(1)
CV
Temperature Coefï¬cient
CV
Temperature Stability
CV
Warm up Drift
(2)
CV
Up programming response time (10-90% or 90-10% of Vmax) CV
Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load
Down programming resp time (CV) (90-10% of Vmax) Zero load
Load Regulation
CC
Load Regulation thermal drift
CC
Line Regulation
CC
Temperature Coefï¬cient
CC
Temperature Stability
CC
Warm up Drift
(2)
CC
Vout & Iout programming & readback resolution Digitally
Vout & Iout programming & readback accuracy Digitally
Voltage & Current Programming
Analog
Voltage & Current Monitoring
Analog
Overvoltage Shutdown (user programmable)
V
Overtemperature Protection
-
Display - Voltage
-
Remote On/Off
-
Output Good
-
Remote Sense Compensation (per wire)
V
Communication Interface
-
Series Operation
-
Parallel Operation
-
Input Voltage / Frequency
(3)
-
Inrush Current
-
Hold Up Time (Typical)
ms
Power Factor Correction
-
Operating Temperature
°C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
-
Insulation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certiï¬cations
-
Immunity
-
Conducted & Radiated EMI
-
Size (H x W x D) (Excluding handles and busbars) mm
Weight
kg
Warranty
yrs
Z10
Z20
Z36
Z60
Z100
2mV + 0.01% of rated voltage over 0 - 100% load change
2mV + 0.01% of rated voltage over a 85 - 132 or 170 - 265VAC line change
1ms
30ppm/°C following 30 minute warm up
0.02% of rated voltage over 8 hours following 30 minute warm up time
<0.05% of rated voltage + 2mV of rated output voltage
15ms
30ms
30ms
50ms
50ms
10ms
30ms
30ms
50ms
50ms
190ms
200ms
250ms
310ms
900ms
5mA + 0.01% of rated current over 0 - 100% Vout change
< 0.05% of rated current over 30 minutes after load change
2mA + 0.01% of rated current over a 85 - 132 or 170 - 265VAC line change
100ppm/°C of rated current after 30 minute warm up time
0.05% of rated current over 8 hours following 30 minute warm up time
<±0.1% of rated current
< 0.012% of rated voltage/current
< 0.05% of rated voltage, < 0.1% of rated current
By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k)
0-5V or 0-10V Voltage (user selectable), ±1% accuracy
0.5 - 12
1 - 24
2 - 40
5 - 66
5 - 110
User selectable - latched or non-latching
4 digits. Accuracy 0.5% of rated voltage or current ±1 count
By applied voltage or dry contact relay (user selectable logic)
Open Collector, Low on fail
1
1
2
3
5
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Up to two identical units (with external diodes)
Up to six units in master-slave conï¬guration
85-265VAC, 47-63Hz
< 25A
16ms
Complies with EN61000-3-2 Class A (0.99 typ)
0 - 50°C
-20 to +85°C
Operating: 10 - 90%RH, Storage 10 - 95%RH
Internal temperature controlled fan
I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min
>100M at 25°C & 70%RH
IEC60068-2-64
<20G, half sine, 11ms. IEC60068-2-27
UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1)
IEC61326 (Designed to meet EN55022 / EN55024)
EN55022-B, FCC part 15-B, VCCI-B
Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm
Standard body 1.9kg; Wide Body 2.4kg
Five Years
Notes:
(1) Recovery to within 0.5% of rated voltage after a load
change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on
(3) Derate for 85-100 VAC; Z10-72-U (66A), Z20-40-U
(36A), Z36-24-U (20A), Z60-14-U (12.5A), Z100-8-U
(7.5A)
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zplus-series.htm
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
121
Revision A6: Sep 2012
|