English
Language : 

Z10-20-U Datasheet, PDF (2/2 Pages) TDK Electronics – 200 to 800W Programmable Power Supplies
Z+ Series
Specifications (See website for detailed specifications)
Model
Load Regulation
CV
Line Regulation
CV
Recovery Time
(1)
CV
Temperature Coefficient
CV
Temperature Stability
CV
Warm up Drift
(2)
CV
Up programming response time (10-90% or 90-10% of Vmax) CV
Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load
Down programming resp time (CV) (90-10% of Vmax) Zero load
Load Regulation
CC
Load Regulation thermal drift
CC
Line Regulation
CC
Temperature Coefficient
CC
Temperature Stability
CC
Warm up Drift
(2)
CC
Vout & Iout programming & readback resolution Digitally
Vout & Iout programming & readback accuracy Digitally
Voltage & Current Programming
Analog
Voltage & Current Monitoring
Analog
Overvoltage Shutdown (user programmable)
V
Overtemperature Protection
-
Display - Voltage
-
Remote On/Off
-
Output Good
-
Remote Sense Compensation (per wire)
V
Communication Interface
-
Series Operation
-
Parallel Operation
-
Input Voltage / Frequency
(3)
-
Inrush Current
-
Hold Up Time (Typical)
ms
Power Factor Correction
-
Operating Temperature
°C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
-
Insulation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications
-
Immunity
-
Conducted & Radiated EMI
-
Size (H x W x D) (Excluding handles and busbars) mm
Weight
kg
Warranty
yrs
Z10
Z20
Z36
Z60
Z100
2mV + 0.01% of rated voltage over 0 - 100% load change
2mV + 0.01% of rated voltage over a 85 - 132 or 170 - 265VAC line change
1ms
30ppm/°C following 30 minute warm up
0.02% of rated voltage over 8 hours following 30 minute warm up time
<0.05% of rated voltage + 2mV of rated output voltage
15ms
30ms
30ms
50ms
50ms
10ms
30ms
30ms
50ms
50ms
190ms
200ms
250ms
310ms
900ms
5mA + 0.01% of rated current over 0 - 100% Vout change
< 0.05% of rated current over 30 minutes after load change
2mA + 0.01% of rated current over a 85 - 132 or 170 - 265VAC line change
100ppm/°C of rated current after 30 minute warm up time
0.05% of rated current over 8 hours following 30 minute warm up time
<±0.1% of rated current
< 0.012% of rated voltage/current
< 0.05% of rated voltage, < 0.1% of rated current
By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k)
0-5V or 0-10V Voltage (user selectable), ±1% accuracy
0.5 - 12
1 - 24
2 - 40
5 - 66
5 - 110
User selectable - latched or non-latching
4 digits. Accuracy 0.5% of rated voltage or current ±1 count
By applied voltage or dry contact relay (user selectable logic)
Open Collector, Low on fail
1
1
2
3
5
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Up to two identical units (with external diodes)
Up to six units in master-slave configuration
85-265VAC, 47-63Hz
< 25A
16ms
Complies with EN61000-3-2 Class A (0.99 typ)
0 - 50°C
-20 to +85°C
Operating: 10 - 90%RH, Storage 10 - 95%RH
Internal temperature controlled fan
I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min
>100M at 25°C & 70%RH
IEC60068-2-64
<20G, half sine, 11ms. IEC60068-2-27
UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1)
IEC61326 (Designed to meet EN55022 / EN55024)
EN55022-B, FCC part 15-B, VCCI-B
Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm
Standard body 1.9kg; Wide Body 2.4kg
Five Years
Notes:
(1) Recovery to within 0.5% of rated voltage after a load
change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on
(3) Derate for 85-100 VAC; Z10-72-U (66A), Z20-40-U
(36A), Z36-24-U (20A), Z60-14-U (12.5A), Z100-8-U
(7.5A)
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zplus-series.htm
1-800-526-2324 • www.us.tdk-lambda.com/lp/
121
Revision A6: Sep 2012